Shenzhen Rogin Medical Co., Ltd
                                                                                                           
Verified Supplier
14 Years
Since 2012
Menu

Low Noise Dental Handpieces And Accessories / Dental Low Speed Handpiece With CE Standard

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: depending on the quantity and sizes
Brand: OEM
Product Description

Dental Low Speed Handpiece Kit Dental Handpiece Repair Kit, Dental External Kit


Features:

 

Contra angle handpiece


Low Speed 22,000-27,000 rpm


The shank of the instrument mounted therein is 2.35 mm


Fastening of the instruments with a turning latch


Autoclavable 135°C


For any lab or E-type motors

 

Color Style Silver
Chuck  Key Type
Spray External water spray
Hole 2 or 4 Holes
Air Pressure 0.3-0.35Mpa
Rotation Speed 14,000-22,000 rpm
Noise ≤65 dB

 

Straight Handpiece


Working pressure: 0.3MPa


0.25MPa(Measure meter is installed at the end of air motor to measure the air pressure)


Revolution: about 22000-27000r/min (adjustable between clockwise or anticlockwise)


Noise: ≤70dB


Air consumption: about 56L/min


Ratio: 1:1


Max speed of contra angle: 25000rpm/min

 

Air Motor:


Supply air pressure: 245-392KPa (2.5-4kgf/CM2)


1:1 Direct Drive


Borden 2 holes/Midwest 4 holes


Max speed 20,000 min-1

 
Air-in Pressure(kg/cm2) Motor Rotation(rpm) Air Wastage:(N1/min)
2.5 22,000 42
3 25,000 51
4 27,000 72

 

WAYS OF LOADING AND UNLOADING BURS:


(1). Straight handpiece: When unloading the bur, please turn the stuck, until you hear a sound.

And loading the bur, you turn the stuck to the opposite side. When you hear a sound, the bur has been fixed

 

(2). Contra angle handpiece: Screw the clip and put the bottom of bur to the axle center, then turn the clip to the original place.

Unloading the bur, screw the clip and take the bur out.

 

CLEAN AND LUBRICATE:


(1). Air motor: Load the pipe from motor. For example drip some lubrication into the air pipe at the bottom.

Lubricate it after every use, drip 2 drops.
(2). Straight handpiece: Turn the spray head to the mouth of lubrication.When unloading the bur, put the spray head to the handpiece and ensure that the head of handpiece show sigh of oil.(at least 2 seconds). Don't invert oil tin when using lubrication.


(3). Contra angle handpiece: Loose the winding part of SH, take the conducting gear out. Lubricate the conducting part.Screw the clip when lubircating the head of handpiece. 

 

CAUTIONS:


Don't use damaged or winding burs. The damaged or winding burs will cause accident if use.


Burs are hard to pull out if the gully part has damaged.


Please keep the clamping part clean, if it was stained, the cartridge will shock or the strength of clamping part will weaken.


Please fix the burs, or the bearings will be damaged at early stage. Don't use motor when the clip is loose or burs are not on.


Please install the burs or standard stick even not in usage.

 

Payment :

 

T/T, Western union, Paypal

 

Packing :

 

It includes Contra Angle Handpiece,Straight Handpiece With Air Motor

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Rogin Medical Co., Ltd
Location 5th Floor, Block I, Jinchangda Science Park, Shangwei insdustry District, Shangkeng community Guanhu Street, Longhua District, Shenzhen 518110 Guangdong, P. R. China
Contact Person Nature Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.