ISO9001 Energy Management System Resolution for Power station service system
System Summarized
Power monitoring system software developed by Kingsine, use computer, communication device, monitoring and control unit, protection devices, etc. This provides a basic platform for real-time data etc.
This electric system can provide “integration and monitoring” resolution. Major contains real-time power acquisition module, energy manage and analysis module, real-time history database. SOE module, SMS warning module. Powers monitoring system software plays a very important role and makes a very good power electrical management effect in electrical system, commercial and public building, infrastructure, automobile, petrochemical, telecommunications, metallurgy, light industry, water treatment and other fields.
Applications Range:
Industry distribution automatic system
Substation automatic system
Power station service system
Energy efficiency management system
Electrical engineering in intelligent
Low voltage switch cabinet
System Instruction
1,Master layer
Master layer contains:Power monitoring system software, monitor host, Database publishing service, Printer, UPS power groups. We have two ways: One server corresponding one client and one server corresponding multi-client.
2,Communication layer(communication device)
Communication layer use Industrial switches and communication manager to achieve On-site monitoring and control device monitoring host connection.
3,Spacer layer(On-site meter)
Power quality monitoring device, PMC serial intelligent meter, Protection relay device and Transformer temperature controller install in spacer layer to achieve the functions as: on-site measurement, monitoring, communication, etc. PMC serials contains: PMC200 Multifunctional power meter, PMC180 Three-Phase Digital Power Meter, PMC180N Three-Phase Network Power Meter, PMC100 Single Phase Digital Power Meter, and PMC100N Single Phase Network Power Meter.
PMC Series Product Selection Table
| Model |
PMC 200 |
PMC 180Z |
PMC 180P |
PMC 180U |
PMC 180I |
PMC 180N |
PMC 100Z |
PMC 100P |
PMC 100U |
PMC 100I |
PMC 100N |
| Real-time Measure | |||||||||||
|
Phase voltage/line voltage/phase current |
◆ | ◆ | ◆ | ◆ | - | ◆ | ◆ | ◆ | ◆ | - | ◆ |
| Active power/reactive power/apparent power | ◆ | ◆ | ◆ | - | ◆ | ◆ | ◆ | ◆ | - | ◆ | ◆ |
| Power factor/frequency | ◆ | ◆ | ◆ | - | - | ◆ | ◆ | ◆ | - | - | ◆ |
| Active energy/reactive energy/apparent energy | ◆ | ◆ | - | - | - | ◆ | ◆ | - | - | - | ◆ |
| Power Quality Monitor | |||||||||||
| Odd/even/Total Harmonic distortion | ◆ | ◆ | - | - | - | ◆ | - | - | - | - | - |
| Single Harmonic | 31times | 31times | - | - | - | 31times | - | - | - | - | - |
| Single Harmonic active/reactive power | - | - | - | - | - | ◆ | - | - | - | - | - |
| Sequence component: Positive sequence/ Negative sequence/Zero sequence | - | - | - | - | - | ◆ | - | - | - | - | - |
| Unbalance degree | - | - | - | - | - | ◆ | - | - | - | - | - |
| Current K factor | - | - | - | - | - | ◆ | - | - | - | - | - |
| Voltage crest factor CF | - | - | - | - | - | ◆ | - | - | - | - | - |
| Overload nature/Phase sequence monitor/Phase angel difference | - | - | - | - | - | ◆ | - | - | - | - | - |
| Other Functions | |||||||||||
| Energy multi-rate | ◆ | - | - | - | - | - | - | - | - | - | - |
| Max/Min/ Instantaneous value | ◆ | - | - | - | - | - | - | - | - | - | - |
| Phase current damand | ◆ | - | - | - | - | - | - | - | - | - | - |
| Active/reactive/apparent damand | ◆ | - | - | - | - | - | - | - | - | - | - |
| Over limit alarm | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
| SOE event record(with time scale) | ◆ | - | - | - | - | - | - | - | - | - | - |
| Display | |||||||||||
| LCD | ◆ | - | - | - | - | - | - | - | - | - | - |
| LED Digital control panel | - | ◆ | ◆ | ◆ | ◆ | - | ◆ | ◆ | ◆ | ◆ | - |
| Communication interface and protocol | |||||||||||
| RS485/MODBUS | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
| RS232/MODBUS | Option | - | - | - | - | - | - | - | - | - | - |
| TCP/IP/MODBUS | Option | - | - | - | - | - | - | - | - | - | - |
| Profibus-DP | Option | - | - | - | - | - | - | - | - | - | - |
| Input/output (option) | |||||||||||
| Binary input DI | 8-channel | 2-channel | 2-channel | 2-channel | 2-channel | - | 2-channel | 2-channel | 2-channel | 2-channel | - |
| Relay output DO | 4-channel | 2-channel | 2-channel | 2-channel | 2-channel | - | 2-channel | 2-channel | 2-channel | 2-channel | - |
| Analog intput AI | 2-channel | - | - | - | - | - | - | - | - | - | - |
| Analog output AO | 2-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel |
| Accuracy class | |||||||||||
| Current/Voltage | 0.2 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level | 0.5 level |
| Power | 0.5 level | 0.5 level | 0.5 level | - | - | 0.5 level | 0.5 level | 0.5 level | - | - | - |
| Active Energy | 1.0 level | 1.0 level | - | - | - | 1.0 level | 1.0 level | - | - | - | 1.0 level |
| Reactive Energy | 2.0 level | 2.0 level | - | - | - | 2.0 level | 2.0 level | - | - | - | 2.0 level |
Get in Touch