HK UPPERBOND INDUSTRIAL LIMITED
                                                                                                           
Verified Supplier
19 Years
Since 2007
Menu
Home & Garden Lighters & Smoking Accessories Other Lighters & Smoking Accessories

Length/ Weight/Circumference/PD/Hardness Cigarette / Filter Rods Tester Device

Price Negotiable
Price: Negotiation
MOQ: 1 Set
Delivery Time: 30 Works Days
Brand: Upper Bond
Product Description

 
Length/ Weight/Circumference/PD/Hardness Cigarette / Filter Rods Tester Device
 
 
 
Introduction
 
This gauge is a comprehensive physical parameter tester for measuring the weight, circumference (roundness), length, draw resistance, ventilation ratio, hardness and other parameters of cigarettes and filter rods based on a modular design concept; The RT comprehensive test gauge improves the test precision, is suitable for samples of various specifications such as thin (medium-thin and ultra-thin) samples and short samples, and has remote diagnosis and maintenance functions.
 

 
Performance and features
 
1. Equipment function: test physical indicators of various cigarettes and filter rods, such as weight, circumference, roundness, length, draw resistance (open type and closed type), ventilation ratio, and hardness;
2. Modular design and draw-type structure; different units can be combined as needed, and specified test functions can be enabled or disabled;
3. Panel-type unit layout, attractive and generous, and conducive to observation of the measurement process and troubleshooting;
4.Feeding device: adopting a full-automatic roller hopper with independent intellectual property rights, and automatic switching to a thick gear, a medium gear or a thin gear by software according to sample brands;
5.Weighing unit: adopting an imported precision balance (capable of preventing electromagnetic interference), having an automatic calibration function, and automatic peeling in the measurement process (to avoid interference from dust and other impurities);
equipped with an electronic level to adjust the levelness of the equipment, so that calibration and measurement errors are avoided;
6. Circumference unit: adopting the patent and proprietary technologies such as a mechanical clamping device, a height stepless adjustment device for special filter rods, double-angle positioning based on hardware and software to test transparent filter rods;
7. Length unit: adopting a mechanical clamping device and a reference positioning device that does not need to be re-calibrated after brand change;
 
8. Draw resistance unit: adopting patent technologies with intellectual property rights, such as island valves, wedge seals, panel filters, temperature and humidity monitors, internal standard bars for automatically calibrating test data (note ①), and anti-static technology;
pressure drop of test tube is less than 10Pa and meets national standard requirements;
9. Hardness unit (air bearing): vertically applying pressure directly with weights, and adopting advanced technologies such as the air bearing zero-friction technology and the laser non-contact measurement technology to ensure that the pressure meets national standard requirements;
automatic centering of samples, and stepless width-range setting of measurement position;
10. Control system: adopting a 15-inch industrial tablet computer as the control computer, adopting a windows 7 operating system, and hanging the computer on the left of the equipment.
11. Data output: equipped with a large-format thermal printer, Ethernet interface and USB interfaces and having data upload capacity;
12. Externally equipped with an alarm light and having a sound-light alarm function;
13. Power supply and gas source: adopting an industrial power supply with high anti-interference capacity; equipped with an oil-water separator and a precision filter to enhance gas source purification;
14. Repair and maintenance: having remote diagnosis and maintenance functions.

 
Optional parts
1. Sorting unit (horizontal sorting to protect the samples and to lower the equipment case)
2. Internal UPS (optional)
 
 
Main technical indicators
1. Sample length range: 55 ~ 150mm
2. Sample circumference range: 15.5 ~ 28.5mm
3. Hopper capacity: >50
4. Operating speed: ≥6/min (excluding hardness test)
5. Sample collection: disordered collection, >200
6. Distance from hardness test point to end face of sample: 0-75mm;
distance from circumference test point to end face of sample: 47-118mm (including two-in-one)


7. Conventional measurement indicators:

Items Measurement range Resolution Precision
Weight 0~200.000g 0.001g ±0.001g
Circumference 15.5-28.5mm 0.001mm ±0.002mm
Length 55-150mm 0.005mm ±0.01mm
Draw resistance 0-10000Pa(optionally, 0-15000Pa) 1Pa ±0.5%FS
Ventilation ratio 0-100% 0.1% ±0.5%FS
Hardness Pre-pressure 10g (adjustable) 0.1g ±1g
Pressure 300g (international) 0.1g ±1g
Time 15.0s (adjustable) 0.1s ±0.1s
Misalignment 0-10mm 0.005mm ±0.01mm
Hardness 0-100% 0.1% ±0.1%

 
Adopting CFOs (17.5 ±0.1 ml/s) made from imported gems to guarantee a constant flow rate, and the flow accuracy of CFOs in a pipeline is 17.5 ± 0.1 ml/s;
*Product parameters may be changed as needed without prior notice.

 
 
Usage environment requirements
 
Environmental temperature: recommended ambient temperature (22 ± 2) °C
Environmental humidity:recommended environmental humidity (60±5)%RH (preferred)
Power supply: AC 220V±10%, frequency 50HZ±5%, power <200W
Compressed air supply: >0.5MPa, 80L/min

 
 
 
PICTURE 
 

 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HK UPPERBOND INDUSTRIAL LIMITED
Location RM 18S, 27/F, HO KING COMM CTR, 2-16 FAYUEN ST, MONGKOK KOWLOON, HONG KONG
Contact Person Tom

Request A Quote

Please check your email address.
Your message must be at least 20 characters.