Water - Cooled Plate Accessory Flow Divider Fitting Shunt Liquid Cooling Plate

Price Negotiable
Price: dollars
MOQ: 100pcs
Delivery Time: not limited
Brand: Uchi
Product Description

Model: OMWH12-H-6-IR-A

 
Version: V1.0
 
Date: 2026-XX-XX
 
Application Scenarios: Electronic liquid cooling systems, high-power industrial power supplies, charging pile BMS, industrial control current sensing
 

1. Product Overview

 
This product is a customized Kelvin lead-type power shunt resistor. It adopts an integrated welding structure of high-conductivity copper alloy resistive element and electrolytic copper bracket.
 
It features low resistance, high current carrying capacity, and high-precision sampling, specially designed for industrial current sensing at hundreds of amperes, suitable for harsh high-temperature and high-vibration working conditions.
 
  1. Welding: Bracket and copper alloy resistive element welded on non‑sheared surfaces; no gaps, cold joints or false welds. Pickling before welding, passivation after welding.
  2. Appearance: Flat, smooth and uniform surface; no burrs, burns, slag, contamination or cracks.
  3. Encapsulation: Welded areas covered with transparent heat‑shrink tube, tight and wrinkle‑free. Leads firmly fixed, color coding clear.
 

6. Test & Acceptance Criteria

 
  1. Factory Test: 100% inspection of resistance (200μΩ±3%), appearance and lead continuity; Factory Test Report issued.
  2. Sampling Test: Per GB/T 2828.1-2012, sampling for withstand voltage, insulation and tensile strength, AQL=0.65.
  3. Acceptance Documents: Factory test report, material certificate, RoHS/REACH compliance (upon request).
 

7. Packaging & Transportation

 
  1. Packaging: Individually packed in anti‑static bags, 50/100 pcs per box. Outer box labeled with model, quantity, date and batch number.
  2. Transportation: Moisture‑proof and anti‑vibration packaging, avoid impact. Comply with RoHS and REACH for international logistics.

 

Core Functions

 
  • Flow Distribution / Collection: Distribute coolant from the main line evenly to multiple cold plates; collect heated fluid from each branch and return it to the cooling source / CDU after heat exchange.
  • Pressure & Resistance Management: Control pressure drop in each branch to prevent local overheating caused by uneven flow.
  • Simplified Piping & Maintenance: Reduce the number of connectors; with quick connectors, single cold plates can be rapidly installed or removed for maintenance.
  • Monitoring & Regulation (High‑end Models): Integrated flow meters, temperature / pressure sensors, and even valves for fine‑tuning flow in each branch.
 

Common Types & Structures

 

By Application

 
  • Manifold (Supply Side): 1 inlet, N outlets.
  • Collector (Return Side): N inlets, 1 outlet; usually used in pairs.
 

By Flow Division Method

 
  • Y‑type / Tee Manifold: 1 inlet, 2 outlets; suitable for small systems with two cold plates.
  • Bar / Row Manifold: 1 inlet, multiple outlets (e.g., 1‑to‑4, 1‑to‑6); commonly used in data centers / mining rigs.
  • Annular Manifold: For closed‑loop liquid cooling circuits.
 

By Adjustability

 
  • Fixed Type: No valves, low cost; flow determined by orifice / channel design.
  • Adjustable Type: Each branch equipped with needle / ball valves; flow adjustable manually or electrically.
 

Material & Interface

 
  • Materials: Mainly aluminum alloy / stainless steel / copper.
     
    Aluminum alloy: lightweight, moderate cost.
     
    Stainless steel: high pressure resistance, good corrosion resistance.
     
    Copper: excellent thermal conductivity but high cost.
     
    Must be compatible with system coolant to prevent corrosion.
  • Interfaces:
     
    PC water cooling: commonly G1/4" thread.
     
    Industrial / data center: flanges, compression fittings, quick connectors (e.g., DME, ISO 8434).
  • Sealing: Must use O‑rings / gaskets to prevent leakage; recommended materials: Nitrile Rubber (NBR) or Fluororubber (FKM).
 

Key Selection Parameters

 
  • Number of Branches & Flow Demand: Ensure sufficient flow for each cold plate to meet cooling requirements and avoid excessive pressure drop.
  • Working Pressure / Temperature: Industrial cold plates typically operate at 0.3–1 MPa, 30–50°C.
  • Flow Resistance & Uniformity: Flow channel design determines flow deviation; high‑end systems require inter‑branch flow deviation < 5%.
  • Interface Size & Compatibility: Match inner diameter of tubing and connector type.
  • Installation Space: Length and height of bar manifolds must fit cabinet / equipment layout.
 

Application Scenarios

 
  • Personal PC / Workstation: Y‑type manifold for CPU + GPU dual cold plates.
  • Data Center AI Servers: Rack‑mount bar manifolds, 1‑to‑8/16 for multi‑GPU cold plates.
  • Miner Clusters: Multi‑branch manifolds cooling multiple hash boards simultaneously.
  • New Energy Vehicle Battery Packs: Centralized supply and return for liquid cooling plates.
 

Installation & Notes

 
  • Separate supply and return lines to avoid thermal short‑circuit.
  • Tighten connectors evenly; torque wrench recommended.
  • Fully vent air during initial system filling.
  • Regularly inspect seal aging to prevent leakage.
  • Install manifold in an easily accessible and observable location.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong Uchi Electronics Co.,Ltd
Location Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
Contact Person Anna

Request A Quote

Please check your email address.
Your message must be at least 20 characters.