Flat High Temperature 10K NTC Temperature Sensor For Industrial 103F34-50W

Price Negotiable
Price: Negotiable
MOQ: 1000PCS
Delivery Time: 7 workdays
Brand: UCHI
Product Description

 

Flat High Temperature 10K NTC Temperature Sensor For Industrial 103F34-50W

 


Specifications
 
1. Electronics specifications
R25: 10K Ohm +/-1%
B 25/85 : 3435k+/-1%
Operating Temperature : -40~120degree
Dissipation constance : 7.5mW/C
Insulation resistance : DC500V    >=100MOHM
Rated power : at 25deg,in still air  500mW
Thermal time constant :  at 25deg,in still air          20sec 
 

 

 

2. Overall dimensions
                                                                                      unite:mm

 


 
3. Environment Test

  ITEM CONDITIONS SPEC SPEC
3-1 High temperature storage 125deg(AIR) 1000Hrs

△R25
△B25/85

+/-1%<3%
+/-1%<2%

3-2 Low temperature storage -40deg(AIR)   1000Hrs

△R25
△B25/85

+/-1%<3%
+/-1%<2%

3-3 High humidity storage 40deg/95%/240Hrs

△R25
△B25/85

+/-1%<3%
+/-1%<2%

3-4 Thermal shock -40deg~125deg/5 cycles

△R25
△B25/85

+/-1%<3%
+/-1%<2%

 
 

 

4. Inspection conditions
 
4-1 Sampling method : Apply to MIL-STD-05D
4-2 Level : Level 1 , AQL 1%
4-3 Check point and method

Check point Test method Grade
Appearance and dimension Refer to 5-2 Important
Electrical characteristics Refer to 5-3 Very important
Mechanical characteristics Refer to 5-4 Very important
Environment test Refer to 5-5 Very important

 

* Follow the special specification if another check point required .

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong Uchi Electronics Co.,Ltd
Location Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
Contact Person Anna

Request A Quote

Please check your email address.
Your message must be at least 20 characters.