IEC EP EN 0.2mm 0.5mm Thermocouple Bare Wire For Thermocouple Extension Alloy Wires
IEC Class One EP EN 0.2mm 0.5mm Thermocouple Wires Used For Thermocouple Extension Alloy Wires
Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
The Type E thermocouple is composed of a nickel-10% chromium (+) versus a nickel-45% copper (-) wire. This Type of thermocouple can be used in oxidizing or inert atmospheres with a service temperature range of -200°C to 900°C (330°F to 1600°F). The Type E thermocouple can be used successfully in subzero applications due to high corrosion resistance to high moisture environments. Out of all of the different types of thermocouples, The Type E has the highest EMF output per degree.
2. Aluminum industry
3. Food and Pharmaceutical
4. Forgings
5. Glass, Ceramics, Clay Tiles, Bricks
6. Heat Treating
7. Petroleum, Downhole Oil & Gas
8. Sensor Manufacturing
9. Steel industry
10. Utilities Power Generation
IEC Class One EP EN 0.2mm 0.5mm Thermocouple Wires Used For Thermocouple Extension Alloy Wires
Shanghai Tankii Thermocouple wire's Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
Tankii products conform to the standards of IEC584 -1and IEC-2.
|
Thermocouple type and index |
Measurement Range ℃ |
|
|
Type |
Index |
|
|
|
B | 600~1700 |
|
|
R | 0~1600 |
|
|
S | 0~1600 |
|
|
K | -200~1300 |
|
|
E | -200~900 |
|
|
J | -40~750 |
|
|
T | -200~350 |
|
|
N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
|
Thermocouple |
Grade |
Temperature range |
Allowable Tolerance /℃ |
| Type B | Ⅱ | 600~1700 | ±0.25% t |
| Ⅲ | 600~800 | ±4 | |
| 800~1700 | ±0.5%t | ||
| Type R(S) | Ⅰ | 0~1100 | ±1 |
| 1100~1600 | ±[1+(t-1100) ×0.3%] | ||
| Ⅱ | 0~600 | ±1.5 | |
| 600~1600 | ±0.25% t | ||
| Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
| Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
| Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
| Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
| Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
| Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
| Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
| Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |