HV220 7.10g/Cm3 Ceramic Kilns FeCrAl Heating Wire
High-temperature Heating FeCrAl APM / TK-APM 216YZ Iron Chromium Aluminum Alloy Wire for ceramic kilns
TK-APM 216YZ Iron Chromium Aluminum Alloy takes refined master alloy as raw material, uses powder metallurgy technology to manufacture alloy ingots, and is manufactured by special cold and hot processing and heat treatment process. The product has the advantages of strong oxidation resistance, good corrosion resistance at high temperature, small creep of electrothermal components, long servicelife at high temperature and small change of resistance. It is suitable for high temperature 1420℃,high power density, corrosive atmosphere, carbon atmosphere and other working environments. It can be used in ceramic kilns, high temperature heat treatment furnaces, laboratory furnaces,electronic industrial furnaces and diffusion furnaces.
Main mechanical properties
Tensile Strength at Room Temperature: 650-750MPa
Elongation rate: 15-25%
hardness: HV220-260
Tensile Strength at 1000℃ Temperature 22-27MPa
High Temperature Durability at 1000 Temperature and 6MPa ≥100h
Mainly composition(Wt%)
| C | Si | Mn | Cr | Al | Fe | |
| Min | - | - | - | 20 | 5.5 | Bal. |
| Max | 0.04 | 0.5 | 0.4 | 22 | 6.0 | Bal. |
Mainly physical properties
density 7.10g/cm3
resistivity 1.45µΩ.m
Resistance Temperature Coefficient(Ct)
| 800℃ | 1000℃ | 1400℃ |
| 1.03 | 1.04 | 1.05 |
Average linear expansion coefficient()
| 20-800℃ | 20-1000℃ | 20-1400℃ |
| 14 | 15 | 16 |
Maximum Continuous Working Temperature 1400℃
Fast life
| 1300℃ | 1350℃ | |
|
Average Fast Life (Hours)
|
110 | 90 |
|
Sagging rate after rupture
|
8 | 11 |
Noted:Testing according to GB/T13300-91 standard method
- Rated Voltage: 220V/380V
- The installation process to avoid knocking, to avoid the damp, hand-held stove wire, they should wear gloves. Wire should be installed after the furnace has remained flat, and prevent surface scratches, dirt, corrosion, or improper installation, by affecting the life of
- In the rated voltage to use. In strong reducing atmosphere, acid atmosphere, an atmosphere of high humidity will affect the use of life;
- Temperature before use should be in dry non-corrosive atmosphere, about 1000 ℃ spend a few hours, so that furnace wire protective film formed on the surface after normal use, so that can guarantee the normal life of furnace wire;
- Furnace installation should ensure that the insulated wire good power to avoid touching furnace after the wire, guard against electric shock or burns.
Specifications
Wire diameter range: φ0.1-8.5mm
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.