Corrosion Resistant Sodium Hypochlorite Dosing System Metering Diaphragm Pump
Price:
NEGOTIATION
MOQ:
1 SET
Delivery Time:
7-15 work days
Brand:
CNJS
Product Description
Corrosion Resistant Sodium Hypochlorite Dosing System Metering Diaphragm Pump
DFD characteristics of electromagnetic diaphragm metering pumps :
1. Corrosion plastic housing ( ABS + polycarbonate ) ;
2. IP65 degree of protection ;
3. The corrosion resistant pump head : PP, PVC, PTFE, SS 316;
The corrosion resistant Diaphragm : Full PTFE diaphragm, a special process structure, never corrupted ;
5. The double ball way valve : sealing effect doubled ;
6. Eye-catching visual user interface : LED digital display of the current metering pump operating frequency or frequency division multiplication factor, five operating buttons ( START / STOP , ∨ , ∧ , A / M , ADJ ) . START / STOP to start and stop the metering pump , ∧ to increase the flow of metering pumps , ∨ for reducing the flow rate of the metering pump . A / M to switch the metering pump works , ADJ for setting various control parameters . Flow 0-100% adjustable , intelligent digital design, analog circuit abandons adjustment potentiometer and linear drift error caused by bad , avoid traffic caused due to loss of lock when adjusting stroke lead to instability phenomenon , making metering pump flow more accurate , higher repeatability ;
7.A wider range of power supply design :180-250VAC 50-60HZ
8.Powerful control functions: metering pump has two operating modes 1) power protection mode: in this case, the metering pump automatically after power is stopped, to prevent the conditions are not met due to other devices automatically start pump dosing damage to to equipment or personal; 2) power storage : in this case , the metering pump automatically into the state before the power failure after power . The original is running , metering pump continues
| Total of three series DFD.DM.DP, details are as follows : |
| DFD series electromagnetic diaphragm | |||||||
| Corrosion plastic | |||||||
| Full PTFE diaphragm | |||||||
| According to protection degree IP55 design | |||||||
| A variety of materialsOptional head :PP,PVC,PTFE,SS316 | |||||||
| Double ball check valve | |||||||
| Frequency adjustment :10-100% | |||||||
| Manual adjustment , paneldisplay | |||||||
| DFD series of electromagnetic diaphragm metering pump selection parameter | |||||||
| Type | Flow L/H | Pressure BAR | Stroke frequency | Suction M | Weight KG | Power | Power supply |
| DFD-02-07-L | 2 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DFD-02-16-X | 2 | 16 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-03-07-L | 3 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DFD-06-05-L | 6 | 5 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DFD-06-07-X | 6 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-09-03-L | 9 | 2 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DFD-09-07-X | 9 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-12-07-X | 12 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-15-03-X | 15 | 3 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-20-03-X | 20 | 3 | 160 | 2 | 3.5 | 65 | 220V 50HZ |
| DFD-30-03-X | 30 | 3 | 160 | 2 | 4 | 65 | 220V 50HZ |
| DFD-50-02-X | 50 | 2 | 160 | 2 | 4 | 65 | 220V 50HZ |
| DM series electromagnetic diaphragm | |||||||
| Corrosion plastic | |||||||
| According to protection degree IP55 design | |||||||
| A variety of materialsOptional head :PP,PVC,PTFE,SS316 | |||||||
| Double ball check valve | |||||||
| Frequency adjustment :10-100% | |||||||
| Stroke adjustment : 10-100% | |||||||
| Acceptable 0 / 4-20MA external current signal, the panel display, the starting point can be set, you can reverse the ratio, automatic adjustment. | |||||||
| Type | Flow L/H | Pressure BAR | Stroke frequency | Suction M | Weight KG | Power | Power supply |
| DM-02-07-L | 2 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DM-02-16-X | 2 | 16 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-03-07-L | 3 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DM-06-05-L | 6 | 5 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DM-06-07-X | 6 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-09-03-L | 9 | 2 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DM-09-07-X | 9 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-12-07-X | 12 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-15-03-X | 15 | 3 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-20-03-X | 20 | 3 | 160 | 2 | 3.5 | 65 | 220V 50HZ |
| DM-30-03-X | 30 | 3 | 160 | 2 | 4 | 65 | 220V 50HZ |
| DM-50-02-X | 50 | 2 | 160 | 2 | 4 | 65 | 220V 50HZ |
| DM series electromagnetic diaphragm | |||||||
| Corrosion plastic | |||||||
| According to protection degree IP55 design | |||||||
| A variety of materialsOptional head :PP,PVC,PTFE,SS316 | |||||||
| Double ball check valve | |||||||
| Frequency adjustment :10-100% | |||||||
| Stroke adjustment : 10-100% | |||||||
| Key operation, receiving the pulse signal, the panel display, built-multiplication, division, automatic adjustment. | |||||||
| Type | Flow L/H | PressureBAR | Stroke frequency | Suction M | Weight KG | Power | Power supply |
| N/M | |||||||
| DP-02-07-L | 2 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DP-02-16-X | 2 | 16 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-03-07-L | 3 | 7 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DP-06-05-L | 6 | 5 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DP-06-07-X | 6 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-09-03-L | 9 | 2 | 120 | 2 | 3.5 | 30 | 220V 50HZ |
| DP-09-07-X | 9 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-12-07-X | 12 | 7 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-15-03-X | 15 | 3 | 120 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-20-03-X | 20 | 3 | 160 | 2 | 3.5 | 65 | 220V 50HZ |
| DP-30-03-X | 30 | 3 | 160 | 2 | 4 | 65 | 220V 50HZ |
| DP-50-02-X | 50 | 2 | 160 | 2 | 4 | 65 | 220V 50HZ |
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Jiashang Environmental Technology Co., LTD
Location
RoomA206 No.455 Xiangmin Rd, Songjiang District, Shanghai , China
Contact Person
Sherry