Portugal Class 1 Din Rail KWH Meter STS Keypad Single Phase Prepaid Electricity With CIU
Portugal Class 1 Din Rail STS Keypad Single Phase Prepaid Electricity Meter with CIU
The CA168-S single phase keypad prepaid electricity meter is a certified meter, compliant with the IEC62053-21, and IEC62055-21/31/41 standards. The split design is designed target for maximum security against fraud, while retaining the customer's convenience. The main measurement and control unit (MCU) is in Din-Rail structure. The MCU is mounted inaccessible for the user while the CIU is installed at a point of convenience within the customer's premises. The user can retrieve the power consumption and other information by the customer interface unit (CIIU). The communication between MCU and CIU performed by the power line carrier (PLC), current loop, RF or other communication definded by the costomer.
Major Features
- Support Bi-directional and Uni-directional measurement
- Neutral current measurement
- Prepayment/post-payment mode switch
- programmable auto scroll display item
- Adjustable power limit trip
- Enhanced tamper detection for magnetic field, reverse connection, cover open, etc.
- Reverse energy measurement SRE
- Information toggled by codes
- Tamper trip protection : neutral missing
Other Benefits
a) Compact and slim-line design
b) PLC/ RF communication for MCU & UIU and same with back end AMI server (On request)
c) Time of Use (TOU) , multi-rate, tariff control, holiday setting
d) 15 year designed life
e) Enhanced revenue protection through flexible payment control
Specifications:
|
Nominal voltage Un |
220/230/240 V |
|
Limited voltage |
70%~120%Un |
|
Nominal frequency fn |
50-60Hz+5% |
|
Basic current(Ib) |
5-10A |
|
Maximum current(Imax) |
60-100A |
|
Starting current(Ist) |
20mA |
|
Active energy constant |
1000imp/kWh |
|
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
|
Power consumption in Voltage circuit |
<2W <8VA |
|
Power consumption in current circuit |
<1VA |
|
Operating temperature |
25℃ to+70℃ |
|
Storage temperature |
40℃ to+85℃ |
|
Insulation level |
4kV rms for 1min |
|
Impulse voltage withstand |
8kV, 1.2/50 μs |
|
Air discharge |
16kV |
|
Immunity to HF fields |
|
|
80MHz to 2GHz with load |
10V/m |
|
100kHz to 1GHz without load |
30V/m |
|
Fast transient burst test |
4kV |
|
Meter shell Protection Rate |
IP54(IEC60529) |
|
Insulation System Classification |
Protective Class II |
Get in Touch