RF Communication Remotely Reading Prepaid Energy Meter For Micro Grid Solar Project
RF Communication Remotely Reading Prepaid Energy Meter
for Micro Grid Solar Project
Revenue collection and monitor are two keys that each one of mini-grid or micro-grid developers want. Card type prepayment meter and PLC communication are frequently used solutions. However none of them fit into Mini-grid scenario. Card type meters usually operate with its manufacturer's proprietary prepayment standard, therefore will not integrate with any other solution. Besides card meters need card contact for any top-up or data exchange, which in reality, gives a lot of trouble such as limit of POS business hours, card loss, card damage. PLC may work in main grid. But mini-grid's unstable power flow vastly interferes PLC communication, which leads to connection loss.
The CA168-s is desinged for this kind of mini grid project, be suitable for 5A, 16A small current in the solar plant, and build in the 433 Mhz RF communication for communication between CIU and meter, furthermore, the built-in RF module lead to the possibility of monitoring remotely, the provider can reading remotely, control the meter remotely, get daily report, monthly report.
Major Features
- Load control, over-load switching automatically
- Programmable under and over voltage trip
- Significant reverse energy measurement SRE
- Enhanced tamper detection
- Multi-Level alarm value enable setup
- Preset delayed reconnection
- IP 54 rating
Utility benefits
- PLC/ RF / GPRS communication for AMR AMI features (On request)
- Time of Use (TOU) , multi-rate, holiday setting
- Easy and quick to install with exisiting wires
- 15 year designed life
- Enhanced revenue protection through flexible payment control
Specifications:
|
Nominal voltage Un |
220/230/240 V |
|
Limited voltage |
70%~120%Un |
|
Nominal frequency fn |
50-60Hz+5% |
|
Basic current(Ib) |
5-10A |
|
Maximum current(Imax) |
60-100A |
|
Starting current(Ist) |
20mA |
|
Active energy constant |
1000imp/kWh |
|
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
|
Power consumption in Voltage circuit |
<2W <8VA |
|
Power consumption in current circuit |
<1VA |
|
Operating temperature |
25℃ to+70℃ |
|
Storage temperature |
40℃ to+85℃ |
|
Insulation level |
4kV rms for 1min |
|
Impulse voltage withstand |
8kV, 1.2/50 μs |
|
Air discharge |
16kV |
|
Immunity to HF fields |
|
|
80MHz to 2GHz with load |
10V/m |
|
100kHz to 1GHz without load |
30V/m |
|
Fast transient burst test |
4kV |
|
Meter shell Protection Rate |
IP54(IEC60529) |
|
Insulation System Classification |
Protective Class II |
Get in Touch