GSM DLMS Split Prepaid Electricity Meters Smart Prepayment Meter
Single Phase GSM DLMS Prepaid Electricity Meters Smart Prepayment Meter
Single Phase GSM DLMS Smart Electricity Meter
Single Phase GSM DLMS Smart Electricity Meter CA168
The CA168 is used for a wide rang of smart metering applications.It combines latest 3DES security encryption technology and modular communication unit. The meter is allowing a basic current of 5 Amp while retaining a maximum current of 80 Amp and extended AMR/AMI functional features. It is a compact design in a BS8565 standard housing and maintains the rugged RF immunity withstand of 30V/m and IP54 rating, allowing it to operate in harsh environments.
The meter works with a plug-in modules for DLMS/COSEM compliant data collection and network communications. This modular design enables utility to select from PLC/RF/GPRS/3G and 4G LTE cellular data newworks according to local conditions at low cost. Upgrade and maintenance will also become cost-effective by replacing the modules only instead of the entire meter.
Major Features
- DLSM/COSEM standard compliant
- Detection of significant reverse energy (SRE)
- IEC62056-21 compliant optical & RS485 port allowing for easy data interrogation
- Disconnects on overload and no credit
- Prepayment and credit mode hot swap
- Programmable load limit and low credit warning
- Detection and record tamper event such as cover open, reversal, black-out, etc.
Utility benefit
- Easy connection to User Interface Unit (UIU) for split type applications
- RF / GPRS wireless communication with a head-end AMR/AMI server
- Time of Use (TOU), multi-tariff, holiday setting.
- Advanced load control and disconnection features
Specifications:
| Nominal voltage Un | 220/230/240 V |
| Limited voltage | 70%~120%Un |
| Nominal frequency fn | 50-60Hz+5% |
| Basic current(Ib) | 5-10A |
| Maximum current(Imax) | 60-100A |
| Starting current(Ist) | 20mA |
| Active energy constant | 1000imp/kWh |
| Accuracy as Active energy to IEC62053‐21 | Class1.0 |
| Power consumption in Voltage circuit | <2W <8VA |
| Power consumption in current circuit | <1VA |
| Operating temperature | 25℃ to+70℃ |
| Storage temperature | 40℃ to+85℃ |
| Insulation level | 4kV rms for 1min |
| Impulse voltage withstand | 8kV, 1.2/50 μs |
| Air discharge | 16kV |
| Immunity to HF fields | |
| 80MHz to 2GHz with load | 10V/m |
| 100kHz to 1GHz without load | 30V/m |
| Fast transient burst test | 4kV |
| Meter shell Protection Rate | IP54(IEC60529) |
| Insulation System Classification | Protective Class II |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.