HCDX-3000A AC Magnetic Particle Flaw Detector 0-3000A

Price Negotiable
Price: USD3730/set - USD4220/set
MOQ: 1 pc
Delivery Time: 20-30 working days after receipt of your payment
Brand: HUATEC
Product Description
HCDX-3000A AC Movable Magnetic Particles Flaw Detector
Product Specifications
Attribute Value
AC current 0-3000A
Power input 380V/50Hz
Automatic demagnetizing current AC 3000A~0 continuously adjustable
Output cable 3 copper-core flexible cables (120mm²) of 3 meters
Remanence stability ≤±5%
Product Description

HCDX-3000 AC Magnetization HWDC DC function Movable Magnetic Particles Flaw Detector

Structure Characteristics
  • Equipped with 10 square three-core cable for power input
  • Protection circuit breaker located below the front operating panel
  • High current wiring copper bar for easy connection of magnetized coil or rod electrode
  • Detachable copper head for rod electrode with copper mesh pad contact
  • Compatible with button switch or foot switch operation
Technical Specifications
AC magnetization current AC 0~3000A (effective value) continuously adjustable, short-time intermittent power
Automatic demagnetizing current AC 3000A~0 continuously adjustable
Output cable 3 copper-core flexible cables (120mm²) of 3 meters
Power supply 380V (two-phase three-wire system) ±10%, 50Hz
Dimensions 750(L)×420(W)×900(H) mm (excluding handle)
Remanence stability ≤±5%
Weight 150kg
Application & Usage
Pre-Use Instructions

Before first use or after long storage, inspect all external and internal components for damage or looseness. Do not disassemble any parts without authorization.

Store and operate in a dry, clean, well-ventilated environment free from corrosive gases, high temperatures, or strong vibrations.

Verify power supply compatibility and connection correctness before switching on.

Operation Procedure
1. Connect power cable to grid and distribution cabinet, then close breaker handle
2. Switch on "Power" - indicator light will activate and exhaust fan will start
3. Connect cable ends to output copper bar and coil/rod electrode
4. Press trigger button or foot switch to initiate AC magnetization
5. Connect rod electrode to workpiece or wind cable around workpiece
6. Adjust current knob to required value and complete magnetization (max 2 seconds)
7. For demagnetization, switch selector to "Demag." and repeat steps 1-7
8. When finished, turn off main power switch and remove accessories
Maintenance Notes
  • Fuse or SCR damage may occur from excessive primary current
  • Adjust potentiometer gradually from minimum position during use
  • Ensure all plugs are properly inserted before connecting to power grid
HCDX-3000A Flaw Detector front view showing control panel HCDX-3000A Flaw Detector side view showing cable connections

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HUATEC GROUP CORPORATION
Location 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
Contact Person Ms. Shifen Yuan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.