QQI Variable Depth Flaw Shim Quality Control Indicators for MPI Inspection

Price Negotiable
Price: Negotiable
MOQ: 1 pc
Delivery Time: 7-10 working days after receipt of your payment
Brand: HUATEC
Product Description

QQI Variable Depth Flaw Shim Quality Control Indicators for MPI Inspection


Standard: JB/T6065-2005,ASME-2007 PAGE Number V

Test piece of magnetic particle     Type: CX-230

Inspection items

The condition, method and demand of the test

Color

Metal surface presents bright silver, no rust. no scratch, no corrosion and so on

Plainness

Put the test piece on bare board, parallel completely. No wrinkle. No burts.the surface’s roughness RA is 0.8um

The size of sheet iron and cutting groove

The side length of test piece tested by milscale is 0.75in×0.75in.

The average thickness of test piece CX-230 is 0.002in.

The artificial defect symbol “o”and symbol“+”tested by precision microscope are both on the center of the test piece.

The diameter of symbol “o”is 0.507in,symbor“+”is 0.25in.

The thickness of test piece CX-230 is 0.002in.

The groove depth is 0.0008in; the groove width is 0.007in.

Quality

The physics and chemistry test show the result that the metal is made from 1005 Steel Park electromagnetic pure iron plate.

The analytic result of raw materials accords with the rule of GB6985,

Test piece of magnetic particle     Type: CX-430

Standard: JB/T6065-2005,ASME-2007 PAGE Number V

Inspection items

The condition, method and demand of the test

Color

Metal surface presents bright silver, no rust. no scratch, no corrosion and so on

Plainness

Put the test piece on bare board, parallel completely. No wrinkle. No burts.the surface’s roughness RA is 0.8um

The size of sheet iron and cutting groove

The side length of test piece tested by milscale is 0.75in×0.75in.the average thickness of test piece CX-430 is 0.004in .The artificial defect symbol “o”and symbol“+”tested by precision microscope are both on the center of the test piece. The diameter of symbol four“o”is 0.507in,symbor“+”is 0.25in.

The thickness of test piece CX-430 is 0.004in.the groove depth is 0.0012in,the

groove width is 0.007in.

Quality

The physics and chemistry test show the result that the metal is made from 1005 Steel Park electromagnetic pure iron plate.

The analytic result of raw materials accords with the rule of GB6985,

Test piece of magnetic particle     Type: 3C2-234

Standard: JB/T6065-2005,ASME-2007 PAGE Number V

Inspection items

The condition, method and demand of the test

Color

Metal surface presents bright silver, no rust. no scratch, no corrosion and so on

Plainness

Put the test piece on bare board, parallel completely. No wrinkle. No burts.the surface’s roughness RA is 0.8um

The size of sheet iron and cutting groove

The side length of test piece tested by milscale is 0.75in×0.75in.the average thickness of test piece 3C2-234 is 0.002in .The artificial defect three“o”tested by precision microscope are all on the center of the test piece.

The diameter of big “o”is 0.507 in,

middle “o”is 0.383in ,small“o”is 0.258in,

Test piece 3C2-234,big“o”, thickness:0.002in ,

groove depth:0.0004in,groove width:0.007in,

middle“o” ,thickness:0.002in,groovc depth:

0.0006in,groove width:0.007in,small“o”,

thickness:0.002in,groove depth:0.0008in,

groove width:0.007in.

Quality

The physics and chemistry test show the result that the metal is made from 1005 Steel Park electromagnetic pure iron plate.

The analytic result of raw materials accords with the rule of GB6985,



Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HUATEC GROUP CORPORATION
Location 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
Contact Person Ms. Shifen Yuan

Request A Quote

Please check your email address.