HUA-900 X-Ray Flaw Detector Densimeter with 0.00-5.00 Density Range and 2mm Aperture
Price:
Negotiable
MOQ:
1 pc
Delivery Time:
3-7 working days
Brand:
HUATEC
Product Description
HUA-900 Series Black & White Densimeter for X-Ray Flaw Detection
The HUA-900 densimeter is a precision instrument developed using advanced computer-assisted technology, delivering accurate readings, exceptional stability, and user-friendly operation. This professional-grade equipment is widely applicable in non-destructive testing, publishing industries, and medical science applications.
Technical Specifications
| Parameter | Specification |
|---|---|
| Density Range | HUA-900A: 0.00-4.00 HUA-900B: 0.00-4.50 HUA-900C: 0.00-5.00 |
| Reading Stability | ±0.02 |
| Measurement Uncertainty | 0.00-2.00: 0.02 2.00-4.50: 0.05 4.50-5.00: 0.08 |
| Power Requirements | 220V ±10%, 50-60Hz |
| Dimensions | 300 × 280 × 115 mm |
| Aperture Diameter | 2mm |
| Display Format | Three-digit numeric display |
| Sampling Time | 0.8 seconds |
| Operating Environment | Temperature: 0℃-40℃ Relative Humidity: ≤85% |
| Power Consumption | Approximately 25W |
| Weight | Approximately 3kg |
Operation Instructions
Measuring Density Values
- Connect to power and press POWER button - display shows "-.--" (5-minute warm-up required)
- Press measuring arm without sample - display shows "E.1"
- Hold measuring arm down while pressing red Zero Setting button - display shows "0.00"
- Release measuring arm - instrument ready for measurement
- Align sample with aperture and press measuring arm - density value displayed
Sample Observation
Turn on the lower left light to illuminate trichromatic fluorescent lights inside the instrument for sample observation.
Important Usage Notes
- Keep away from dust, humidity, alkaline/acid substances, and magnetic fields
- Use cohesive tape to remove aperture diaphragm for cleaning with writing brush
- Do not remove factory-installed cohesive tape from aperture diaphragm
- Keep density tablet clean - use only for instrument calibration verification
- Out-of-range measurements still provide reference data value
Each densimeter includes a precision density tablet for accuracy verification and calibration.