Product Description
Ultrasonic Test Block,Calibration Blocks, Test Blocks, A2 UT Blocks, Standard Test Blocks Iiw,BS2704 Standard ISO2400-19
Calibration Blocks/Standard Test Blocks/ UT Blocks
ut calibration blocks
calibration blocks
iiw v1 block
v1 block calibration
a2 block calibration
| Order Code | Shape (Not to Scale) |
Type | Description /Application |
Standard Made To | Material Size |
| V1 | ![]() |
A2
(BS) IIW V-1
|
I.I.W Calibration Standard. Calibration of Shear and compression wave probes. Checking beam angle, emergent point and resolution. Calibration of time base and gain settings. |
B.S. 2704
DIN 54120 IIW (International Institute of Welding) ISO2400 2012
ISO2400-1972
|
Steel
25x100x300mm
|
| V1/50 | ![]() |
A2
(BS)
IIW V2 |
Generally as V1. Thicker block minimises side wall echoes. | BS 2704 |
Steel
50x100x300mm
|
| V2 (Specify hole diameter) |
![]() |
A4 (BS) |
Small calibration block for site checking of shear wave probes, time base and gain. 1.5mm or 5mm diameter hole target |
BS 2704
IOW (Institute of Welding) ISO7963
|
Steel
12.5x43x75mm
|
| V2/20 (Specify hole diameter) |
![]() |
A4 (BS) |
Generally as V2. Thicker block eliminates side wall echoes. 1.5mm or 5mm diameter hole target. |
BS 2704
ISO7963
|
Steel
20x43x75mm
|
| BCB | ![]() |
A5 (BS) |
Beam Calibration Block. Beam profile and resolution checks for shear wave probes. Sensitivity checks for shear and compression probes. 9 off 1.5mm holes. | BS 2704 |
Steel
50x75x305mm
|
| A6 | ![]() |
A6 (BS) |
Evaluating dominant frequency, pulse, length, dead zone and resolving power for shear and compression probes as BS4331 part 3, 1974. | BS 2704 |
Steel
25x50x150mm
|
| RTB | ![]() |
A7 (BS) |
Checking shear wave probe resolution as BS4331 part 3, 1974. Steps of 2, 3, 4 and 5mm. | BS 2704 |
Steel
74mm radius
75mm thick |
| LSW | ![]() |
SPECIAL | Ladder step wedge for timebase calibration with thickness measuring compression probes. 8 steps from 1mm to 8mm. | Tolerance of +0.000mm- -0.040mm |
Steel
8x15x120mm
|
| LSW/M | ![]() |
SPECIAL | Generally as LSW with 15mm diameter steel inserts mounted in plastic. 8 steps from 1mm to 8mm. | Tolerance of +0.000mm- -0.040mm |
Steel inserts
Plastic body 10x20x140mm
|
| CSW | ![]() |
SPECIAL | Curved Step wedge for timebase calibration of thickness measuring probes. 5 steps - 2, 4, 6, 8 and 10mm. | Tolerance of +0.000mm- -0.040mm |
Steel
100mm long
x 30mm I.D. Quadrant |
| MU | ![]() |
SPECIAL | Metric Universal Block for general purpose checking as V1 block. | Tolerance of 0.1mm |
Steel
20x50x150mm
|
| TBR 2 125 (3) | ![]() |
SPECIAL | Radiused test block for calibration of boiler probes. 3 off 1.5mm holes. | Tolerance of 0.004 inch |
Steel
20x25x165mm
|
| TBR 2 125 (5) | ![]() |
SPECIAL | As TBR 2 125(3) - supplied with 5 off 1.5mm holes | Tolerance of 0.004 inch |
Steel
20x25x165mm
|
| A5 Blank Type B | ![]() |
ESI | Determination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole. | ESI 98-7 |
Steel
50x75x305mm
|
| A5 Blank Type C | ![]() |
ESI | Determination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole. | ESI 98-7 |
Steel
50x75x305mm
|
| ESI-BCB N-A5 |
![]() |
ESI | Checking twin crystal probes for sensitivity. Contains four additional 1.5mm diameter holes to A5 block. | ESI 98-2 |
Steel
50x75x305mm
|
| 50 RAD | ![]() |
ESI | Checking pulse shape of shear wave probes. | ESI 98-2 and ESI 98-8 |
Steel
50x75x150mm
|
| ASME (Specify Thickness) |
![]() |
ASME | Setting sensitivity levels for weld testing. Sizes and locations of flaws are dependent on weld thickness. | ASME Article 5 Fig T-546.1 |
Steel
Size dependent on weld thickness
|
| ASME/M (Specify Thickness) |
![]() |
SPECIAL (ASME) |
Metric equivalent of ASME block. | Tolerance of 0.1mm |
Steel
Size dependent on weld thickness
|
| DAC (Specify Thickness) |
![]() |
SPECIAL | Setting DAC characteristics for shear wave and compression wave probes. Flaws typically 1.5mm diameter holes at 20%, 40%, 60% and 80% of thickness. | Tolerance of 0.0004 inch |
Steel
Size dependent on product thickness
|