Patient Monitor signal ECG Medical Simulator Machine With 2 Type Waveform ECG simulator

Price Negotiable
Price: Negotiate
MOQ: 1 unit
Delivery Time: Within 7 days
Brand: Precise Life
Product Description

ECG simulator 10 leads ECG machine simulator with 2 type waveform patient monitor simulator build-in battery

 

 

Feature of medical simulator:

 

 

1.Rechargeable Lithium battery

 

 

2.10 pcs multi-functional ECG connector, can be connect with different type ECG machine cable or patient monitor cable

 

 

3.Battery power indicate light

 

 

4.Low battery power automatic turn off function, protect the Lithium battery

 


 


Specification of simulator:

 

The simulator can generate 2 types waveform
1.Normal ECG waveform
2.Plus-minus triangular waveform

 

 

Dimension: 15x10x3cm
N.W.: 0.35kg



Note:


1.The simulator will automatically generate Normal ECG waveform when connect to power
2.The LED display will be off automatically if without operation after 5 seconds, press any key will be returned to display


Key Description:

There are 4 keys, followed by selection keys, increase key, reducing key, the Enter key, in addition to a set of key combinations

Select Key:

 

This key is used to select the parameter you want to change; there are 4 LED tubes to display the four codes represent what is displayed,
The 1st LED representative waveform code, LED 2-4 representatives the parameter (2 is the value of one hundred, 3 representatives of ten, 4 representatives of bits)

 

Operating method described separately for each waveform:

1. Normal ECG waveform:

Heart rate setting range: 10-200bpm; (initial value: 60 bpm)
Signal amplitude fixed.

2. Plus-minus triangular waveform:
Frequency range: 10-300bpm; (initial value: 75 bpm)
Amplitude range: 0.1-4Mv (10: 0.1mV, 400: 4mV);

2 modes, Mode 1: Positive waveform; mode II: negative waveform; Use combinations key to choose.

Note: The signal amplitude settings:

amplitude range: 0.1mV-4mV (10: 0.1mV, 400: 4mV); (initial value: 100)
Please note that this amplitude setting will affect all waveforms.
Please note that the signal amplitude settings do not affect the amplitude of the ECG waveform.

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Precise life group limited
Location B Block,Duocai Kechuangyuan,No.5 Guanle Rd,Guanhu str.Shenzhe,China
Contact Person Michael

Request A Quote

Please check your email address.
Your message must be at least 20 characters.