Multi- Sensor Smoke And Heat Detector For Commercial Fire Alarm System
Product Overview
This point-type multisensor smoke and heat detector is an intelligent fire alarm detector designed for commercial buildings, integrating smoke detection and temperature detection into one unit. Built with a dedicated microprocessor, it simultaneously monitors environmental smoke concentration and temperature changes. When smoke concentration reaches the alarm threshold or temperature meets the set conditions, the detector immediately uploads alarm information to the fire alarm control panel, achieving rapid and reliable fire warning. The product adopts non-polarized two-bus technology, supports long-distance communication, and can seamlessly connect with XINGJIN Fire series controllers, providing comprehensive fire detection protection for various commercial premises.
Applicable Places
This detector is widely used in the following commercial and public buildings:
-
Commercial Complexes: Shopping malls, department stores, brand specialty stores, supermarkets
-
Office Buildings: Office towers, business centers, industrial park offices, co-working spaces
-
Public Facilities: Hospitals, schools, libraries, cinemas, exhibition halls, museums
-
Transportation Hubs: Airport terminals, railway stations, subway stations, passenger transport centers
-
Hotels & Restaurants: Star-rated hotels, business hotels, restaurants, banquet halls
-
Educational & Cultural Places: Teaching buildings, laboratories, conference rooms, lecture halls
Performance Parameters
Environmental Characteristics
Parameter Value Operating Temperature -10~+50℃ Storage Temperature -20~+65℃ Relative Humidity ≤95% (No condensation) Explosion-Proof Characteristics
Parameter Value Explosion-Proof Mark Not applicable Electrical Characteristics
Parameter Value Operating Voltage 11 Protocol: Bus DC24V (DC18V~28V) modulated, provided by controller
62 Protocol: Bus DC24V (DC13V~28V) modulated, provided by controllerRF Electromagnetic Field Immunity 30V/m Monitoring Current ≤ 150μA (DC24V) Starting Current ≤ 400μA (DC24V) Indicator Light Normal monitoring status: Red flashing LED
Alarm status: Red constant LEDCommunication Characteristics
Parameter Value Wiring System Non-polarity two-wire bus Addressing Range 11S Protocol: 1~200
62 Protocol: 1~252Addressing Method Encoder addressing Max Transmission Distance 1000m (Conductor cross-section ≥1.0mm²) Compatibility
Parameter Value Compatible Controllers JBF-11SF, JBF-11SF-C, JBF50XX, JBF51S series, etc. Mechanical Characteristics
Parameter Value Appearance Color PANTONE Warm Gray 1C Housing Material Plastic Product Weight 96g Dimensions Φ100mm × H53mm (including base) Detection Characteristics
Parameter Value Protection Area 20-30m² Thermal Classification A2R (factory default), BS Core Advantages
1. Dual Detection Accurate and Reliable
The detector integrates dual functions of smoke detection and temperature detection. It is equipped with a dedicated fire detection microprocessor and combines advanced fire detection intelligent algorithms. It can simultaneously identify changes in smoke concentration and environmental temperature. When the smoke concentration reaches the alarm threshold or the temperature meets the requirements of A2R or BS categories, it will immediately upload the alarm information. The dual verification mechanism effectively distinguishes between real fires and environmental disturbances, minimizing false alarms and avoiding personnel evacuations and business interruptions caused by false alarms in commercial premises.
2. Ultra-Low Power Consumption Long-Distance Communication
Adopting non-polarized two-bus technology, the standby current is as low as 150μA, and the alarm current does not exceed 400μA, achieving extremely low power consumption. The communication distance can reach up to 1000 meters, supporting coverage of large commercial buildings. The non-polarized bus design eliminates the need for polarity distinction during wiring, significantly reducing installation difficulty and labor costs. It supports addressing ranges of 1-200 points for 11 protocol or 1-252 points for 62 protocol, meeting the requirements of medium to large commercial projects.
3. Strong Anti-Interference Stable and Reliable
The radio frequency electromagnetic field immunity reaches 30V/m, far exceeding industry standards, ensuring stable operation in complex electromagnetic environments found in shopping malls (such as wireless signals, intercom systems, and electronic equipment interference). The hardware circuit is highly integrated using SMT surface mount technology, ensuring stable and reliable performance. It features temperature sensor abnormality alarm function, timely detecting equipment faults to ensure the system always operates normally.
4. Intelligent Addressing Easy Maintenance
Supports on-site addressing with electronic programmers, with flexible addressing ranges, facilitating engineering commissioning and later maintenance. The plug-in structure design makes installation and removal simple and convenient. The detector can be easily removed for cleaning or replacement without rewiring. The indicator light flashes red in normal monitoring status and stays red in alarm status, providing clear status indication for easy daily inspection.
5. Standards Compliance Quality Assurance
The product is strictly designed and manufactured according to national standards, complying with GB 4715-2005, GB 4716-2005, and Q/JBF001-2019 requirements. It has passed the inspection of the National Center for Quality Supervision and Testing of Fire Electronic Products, ensuring reliable quality and trustworthiness.
Technical Specifications
Parameter Specification Operating Voltage Bus DC24V (DC18V~28V) modulated, provided by controller Standby Current ≤150μA (DC24V) Alarm Current ≤400μA (DC24V) Indicator Light Standby: Flashing red; Alarm: Steady red Wiring Method Non-polarized two-bus Addressing Range 11 protocol: 1-200; 62 protocol: 1-252 Addressing Method Electronic programmer Max Transmission Distance 1000m (conductor cross-section ≥1.0mm²) Operating Temperature -10℃ to +50℃ Storage Temperature -20℃ to +65℃ Relative Humidity ≤95% (non-condensing) RF Immunity 30V/m Heat Sensitivity Class A2R (default), BS Protection Area 20-30m² Dimensions Φ100mm × H53mm (including base) Weight 96g Housing Material Plastic, off-white Commercial Application Value
Reduce Operational Risks: Accurate dual-detection technology effectively identifies real fires, reducing false alarm rates and avoiding unnecessary evacuation and business losses in commercial premises, ensuring normal business operations.
Enhance Safety Levels: Simultaneously monitoring smoke and temperature changes provides good response to both smoldering and open fires, offering more comprehensive fire protection for commercial buildings and safeguarding personnel and property.
Save Construction Costs: Non-polarized two-bus design simplifies wiring processes, saving cable and labor costs; long-distance communication capability reduces the need for relay equipment, lowering overall system costs.
Simplify Maintenance: On-site address modification with electronic programmers, plug-in structure for easy replacement, and intuitive indicator light status significantly reduce the workload of property maintenance teams.
Installation and Usage Instructions
-
Wiring Requirements: Use flame-retardant twisted pair with conductor cross-section ≥1.0mm² (ZR-RVS 2×1.0mm²). Connect L1 and L2 to base terminals L1 and L2 respectively, no polarity distinction required.
-
Installation Steps: Secure the base to the pre-embedded box with two M4 screws; write the address using a programmer; insert the detector into the base and tighten clockwise.
-
Dust Protection: Do not remove the dust cover before the detector is put into use to avoid dust contamination affecting performance.
-
Commissioning Method: After installation, operate the controller for registration; use a specialized temperature gun to heat the grid holes or perform smoke testing; the indicator light stays on when the detector alarms; reset the controller to return to normal monitoring.
-
Regular Maintenance: It is recommended to conduct alarm tests every six months; according to GB29837-2013, the product service life generally does not exceed 12 years.
Precautions
-
During use, installation and operation must strictly follow the requirements of this manual
-
The detector should not be installed in places with high wind speed, excessive oil smoke, or frequent steam
-
The company reserves the right of final interpretation of this manual without prior notice
-
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.