Cisco Router Module Cisco ASR 9000 Adapter SPA-1XCHSTM1/OC3 1-port Channelized STM-1/OC-3c to DS0 Shared Port Adapter
2960 SFP Module SPA-1XCHSTM1/OC3 1-Port Channelized STM-1/OC-3 to DS-0
Cisco SPA-1XCHSTM1/OC3 Specification:
-
SPA-1XCHSTM1/OC3 Specifications
Product compatibility · Cisco 7600 Series Routers
· Cisco ASR 1000 Series Routers
· Cisco ASR 9000 Series Routers
Minimum software version · Cisco 7600 Series Routers: Cisco IOS® Software Release 15.4(2)S and Cisco IOS XE Software Release 3.12.0.0S
· Cisco ASR 1000 Series Routers with Cisco IOS XE Software Releases 3.12.0,3.11.2, and 3.10.3
· Cisco ASR 9000 Series Routers with Cisco IOS XR Software Release 5.2.0
Protocols Serial encapsulations:
· High-Level Data Link Control (HDLC)
· Point-to-Point Protocol (PPP), RFC 1662
· Frame Relay, RFC 1490
Multilink support (bundle limit dependent on number of links per bundle; maximum of 12 links per bundle):
· Multilink PPP (MLPPP), RFC 1990
· Link fragmentation and interleaving (LFI) over Frame Relay (FRF.12) and MLPPP
Networking protocols:
· IPv4/IPv6
Cards, ports, and slots 1 port Connectivity OC-3/STM-1 Small Form-Factor Pluggable (SFP) optics module (refer to optical parameters in Table 2) Features and functions Up to 84 T1 (or 3 T3) or 63 E1 (or 3 E3) ports
Up to 1022 n x DS-0 channels (where n is 1 to 24) with no T3 ports configured
Up to 400 n x DS-0 channels (where n is 1 to 24) with one or more T3 ports configured
Support for Channelized OC-3 to T1, Channelized STM-1 to E1, clear channel T3/E3, subrate T3/E3, full-rate T1, clear channel E1, and Channelized T1/E1
SONET multiplexing:
· OC-3 <-> STS-3 <-> STS-1 <-> VTG <-> VT1.5 <-> T1 <-> N x DS-0
· OC-3 <-> STS-3 <-> STS-1 <-> T3 <-> T1 <-> N x DS-0
· OC-3 <-> STS-3 <-> STS-1 <-> T3
· OC-3 <-> STS-3 <-> STS-1 <-> T3 <-> E1 <-> n x DS-0
SDH multiplexing:
· STM-1 <-> AUG <-> AU-4 <-> VC-4 <-> TUG-3 <-> TUG-2 <-> TU-12 <-> VC-12 <-> E1 <-> n x DS-0
· STM-1 <-> AUG <-> AU-4 <-> VC-4 <-> TUG-3 <-> TU-3 <-> VC-3 <-> T3/E3
· Internal or line-derived (loop) clocking, independently selectable on each T1 or E1 tributary
Loopback capabilities:
· Local and remote loopback at the T3/T1 level
· Network loopback at the STM-1/OC-3, T3/E3, and T1/E1 levels
· Response to embedded loopback commands
· Insertion of loopback commands into transmitted signal
· Bit error rate testing (BERT) pattern generation and detection per channel
· Programmable pseudorandom pattern up to 32 bits in length
· T3/E3: All 0s, all 1s, 215, 220, 220 QRSS, 223, alternating 0s and 1s, 1-in-8, and 3-in-24
· T1/E1: All 0s, all 1s, 211, 215, 220, 220 QRSS, 223, alternating 0s and 1s, 1-in-8, and 3-in-24
· 32-bit error-count and bit-count registers
· Detection of test patterns with bit error rates up to 10-2
· 24-hour history maintained for error statistics and failure counts, at 15-minute intervals
· 16- and 32-bit cyclic redundancy check (CRC); 16-bit default
SONET/SDH-specific features:
· Compliance with G.707, G.783, G.784, G.957, G.958, and GR-253
· Supported SONET/SDH alarm and signal events:
◦ Signal failure bit error rate (SF-BER)
◦ Signal degrade bit error rate (SD-BER)
◦ Signal label payload construction (C2)
◦ Path trace byte (J1)
· Section
◦ Loss of signal (LoS)
◦ Loss of frame (LoF)
◦ Error counts for B1
Line
· Line alarm indication signal (LAIS)
· Line remote defect indication (LRDI)
· Line remote error indication (LREI)
· Error counts for B2
Path
· Path alarm indication signal (PAIS)
· Path remote defect indication (PRDI)
· Path remote error indication (PREI)
· Error counts for B3
· Loss of pointer (LOP)
· New pointer events (NEWPTR)
· Positive stuffing event (PSE)
· Negative stuffing event (NSE)
· Path unequipped indication signal (PUNEQ)
· Path payload mismatch indication signal (PPLM)
T3-specific features:
· Channelized T3 with 28 DS-1 lines or 21 E1 lines multiplexed into a T3
· Unchannelized T3 supporting subrate and scrambling formats for Digital Link, ADC/Kentrox, Larscom, Adtran, and Verilink data service units (DSUs)
· C-bit or M23/M13 framing
· Maintenance data link (MDL)
· T3 far-end alarm and control (FEAC) channel support
· Alarm monitoring
· Alarm indication signal (AIS)
· Out of frame (OOF)
· Far-end receive failure (FERF)
· Performance data collection:
◦ Framing bit errors (FERR) (F- or M-bit errors)
◦ P-bit error counts (path-parity errors)
◦ C-bit error counts
◦ Far-end block error (FEBE) counts
E3-specific features:
· G.751 framing
· Alarm monitoring
· AIS
· OOF
· FERF
· Performance data collection:
◦ Framing pattern errors
◦ BIP-8 error counts (path-parity errors)
◦ FEBE counts
· T1-specific features:
◦ D4 Super Frame (SF) or Extended Super Frame (ESF) framing
◦ ANSI T1.403 and AT&T TR 54016 Facility Data Link (FDL) support
◦ Alarm monitoring
◦ AIS
◦ OOF
◦ Far-end alarm failure (yellow or distant alarm)
Performance data collection:
· CRC/bit errors
· Framing bit errors
· Line errored seconds
· Far-end errored seconds
· Far-end severely errored seconds
· Far-end unavailable seconds
E1-specific features:
· CRC4 or non-CRC4 framing in conformance with ITU-T G.703 and G.704
· Alarm monitoring
· AIS
· OOF
· Remote alarm indication (RAI)
· Performance data collection
· CRC/bit errors
· Framing bit errors
· FEBE
Reliability and availability OIR
Field-replaceable SFP optics modules
Support for both 1 + 1 SONET Automatic Protection Switching (APS) and SDH Linear Multiplexer Section Protection (MSP) protocols
Single SPA software reset
MIBs RFC 2558 MIB (SONET/SDH)
RFC 2495 MIB (T1/E1)
RFC 2496 MIB (T3/E3)
Network management Simple Network Management Protocol (SNMP) Physical specifications Weight: 0.75 lb (0.34 kg)
Height: 0.8 in. (2.03 cm)
Width: 6.75 in. (17.15 cm)
Depth: 7.28 in. (18.49 cm)
Regulatory compliance CE marking
Safety: UL/CSA/IEC/EN 60950-1, IEC/EN 60825 Laser Safety, AS/NZS 60950, FDA Code of Federal Regulations Laser Safety
EMC: FCC Part 15 Class A, ICES 003 Class A, AS/NZS 3548 Class A, CISPR 22 Class B (up to 1GHz), EN55022 Class B (up to 1GHz), VCCI Class A, BSMI Class A, EN 300 386 Telecommunications Network Equipment (EMC), EN50082-1/EN61000-6-1 Generic Immunity Standard, EN55022 Information Technology Equipment (Emissions), EN55024 Information Technology Equipment (Immunity), IEC/EN61000-3-2 Power Line Harmonics, IEC/EN61000-3-3 Voltage Fluctuations and Flicker, IEC/EN61000-4-2 Electrostatic Discharge Immunity (8kV contact, 15kV air), IEC/EN61000-4-3 Radiated Immunity (10V/m), IEC/EN61000-4-4 Electrical Fast Transient Immunity (2kV power, 1kV signal), IEC/EN61000-4-5 Surge AC Port (4kV CM, 2kV DM), IEC/EN61000-4-5 Surge Signal Port (1kV), IEC/EN61000-4-5 Surge DC Port (1kV), IEC/EN61000-4-6 Immunity to Conducted Disturbances (10Vrms), IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity (30A/m), IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations, GR-1089-CORE NEBS EMC and Safety, GR-63-CORE NEBS Physical Protection, SR-3580 NEBS Criteria Levels (Level 3)
Telecom (OC3): GR-253
Telecom (STM-1): G.783, G.957
Environmental Specifications Operating temperature: 41 to 104°F (5 to 40°C)
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating humidity: 5 to 85% relative humidity
Storage humidity: 5 to 95% relative humidity
-
Ordering infomation:
| HWIC-1DSU-T1 | 1-Port T1/Fractional T1 DSU/CSU WAN Interface Card |
| HWIC-1DSU-T1= | 1-Port T1/Fractional T1 DSU/CSU WAN Interface Card |
| HWIC-1T | 1-Port Serial WAN Interface Card |
| HWIC-1T= | 1-Port Serial WAN Interface Card |
| HWIC-2A/S | 2-Port Async/Sync Serial WAN Interface Card |
| HWIC-2A/S= | 2-Port Async/Sync Serial WAN Interface Card |
| HWIC-2T | 2-Port Serial WAN Interface Card |
| HWIC-2T= | 2-Port Serial WAN Interface Card |
| HWIC-1FE | 1-port 10/100 Routed Port HWIC |
| HWIC-1FE= | 1-port 10/100 Routed Port HWIC |
| HWIC-2FE | Two 10/100 routed port HWIC |
| HWIC-2FE= | Two 10/100 routed port HWIC |
| HWIC-2SHDSL | 2-pair G.SHDSL HWIC |
| HWIC-2SHDSL= | 2-pair G.SHDSL HWIC |
| HWIC-1CE1T1-PRI | 1 port channelized T1/E1 and PRI HWIC (data only) |
| HWIC-2CE1T1-PRI | 2 port channelized T1/E1, and PRI HWIC (data only) |
| HWIC-4T1/E1 | 4 port clear channel T1/E1 HWIC |
| HWIC-1CE1T1-PRI= | 1 port channelized T1/E1 and PRI HWIC (data only) |
| HWIC-2CE1T1-PRI= | 2 port channelized T1/E1 and PRI HWIC (data only) |
| HWIC-4T1/E1= | 4 port clear channel T1/E1 HWIC |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.