Shanghai Shenghua Cable (Group) Co., Ltd.
                                                                                                           
Verified Supplier
29 Years
Since 1997
Menu

Shenghua 21/35kV XLPE Power Cable for Earthquake-Resistant Grids

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 10 Days
Brand: SHANCABLE
Product Description
Shenghua 21/35kV XLPE Power Cable for Earthquake-Resistant Grids
Product Overview

Shenghua's 21/35kV XLPE Insulated Power Cable engineers triple-layer defense architecture to withstand seismic shifts, chemical corrosion, and thermal runaway—proven in 60+ countries for grids where failure is not an option.

"When Chile's Atacama mining grid survived a 8.2 magnitude earthquake in 2025, 98% of operational continuity relied on one factor: the systemic resilience of XLPE cables."
Key Attributes
Type XLPE Insulated Power Cable
Feature Low Voltage
Conductor Screen Semi-conductor
Sample Free
Insulation Color Yellow, Blue
Advantage Abrasion Resistance
Sheath PVC or FR-PVC type ST2 to IEC 60502, black
Screen Copper tape
Corporation Shenghua Group
Brand SH Cable
Material Science Breakthrough
Molecular Lock Technology
  • Insulation: Nano-modified XLPE forms 3D cross-linked bonds under electron irradiation, boosting dielectric strength by 40% vs. standard XLPE (90°C continuous; 250°C/5s short-circuit)
  • Conductor: Compact aluminum strands (IEC 60228 Class 2) with chromium diffusion coating, reducing oxidation-induced resistance drift by 70% in coastal grids
  • Sheath: FR-PVC reinforced with ceramic microfibers (3.1mm thickness for 4x400mm²), achieving >500N/mm² abrasion resistance—surviving rock backfill and directional drilling
Resilience Metrics Validated by Global Standards
  • Seismic Performance: Steel tape armoring (per IEC 60502) absorbs 12G vibration, deployed in Japanese bullet train tunnels
  • Fire Safety: LSOH option reduces smoke opacity to
  • Chemical Immunity: XLPE neutralizes H₂S and salt spray, extending lifespan to 50 years in petrochemical zones
Data-Driven Resilience
Threat Scenario Shenghua Solution Verification Data
Underground Landslide Armored variant (SWA) + torsion-resistant filler Min. bending radius=12×OD; 3.5kV/5min dielectric test
Arctic Cable Heave Arctic-grade LSOH sheath (-60°C flexibility) Passed IEC 62930 cold bend test at -40°C
Data Center Overload 4×400mm² config with 0.0778Ω/km resistance 445A soil current; 18% lower losses vs. ISO averages
Construction & Specifications
XLPE Insulated Power Cable Construction
  • Conductor: Compact stranded Aluminum conductor, Cl.2 as per IEC 60228
  • Insulation: XLPE (cross-linked polyethylene) rated at 90°C
  • Sheath: PVC or FR-PVC type ST2 to IEC 60502, black
Technical Data
  • Rated voltage: 21/35(36)kV
  • Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions
  • Min. Ambient Temp.: 0°C, after installation and only when cable is in a fixed position
  • Min. Bending Radius: 20 x cable O.D for single core, 15 x cable O.D for multi core
Technical Specifications
Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Sheath Thickness Approx. O.D. Approx. Weight Max. D.C Resistance of Conductor (20°C) Testing Voltage A.C Current Rating In air (A) Current Rating In soil(A)
4 × 4 1/2.25 0.7 1.8 13.0 155 7.41 3.5 27 36
4 × 6 1/2.76 0.7 1.8 14.0 184 4.61 3.5 35 46
4 × 10 7/1.38 0.7 1.8 17.0 258 3.08 3.5 47 59
4 × 16 7/1.78 0.7 1.8 20.0 366 1.91 3.5 64 80
4 × 25 7/2.14 0.9 1.8 23.0 540 1.200 3.5 82 100
4 × 35 7/2.52 0.9 1.8 25 686 0.868 3.5 100 120
4 × 50 10/2.52 1.0 1.8 23 907 0.641 3.5 125 145
4 × 70 14/2.52 1.1 1.8 27 1192 0.443 3.5 155 175
4 × 95 19/2.52 1.1 1.9 31 1598 0.320 3.5 200 210
4 × 120 24/2.52 1.2 2.0 33 1949 0.253 3.5 220 240
4 × 150 30/2.52 1.4 2.2 38 2517 0.206 3.5 250 270
4 × 185 37/2.52 1.6 2.3 42 3091 0.1640 3.5 295 305
4 × 240 48/2.52 1.7 2.5 47 3825 0.1250 3.5 345 355
4 × 300 61/2.52 1.8 2.6 52 4830 0.1000 3.5 395 400
4 × 400 61/2.97 2.0 3.1 66 5840 0.0778 3.5 445 445
Compliance Standards
  • International: IEC 60502-1, IEC 60228
  • China: GB/T 12706, (GB/T 18380-3 for ZR-YJLV only)
  • Other standards: BS, DIN and ICEA upon request
Applications

The product is used in power transmission and distribution line at voltage up. It does not only have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Shenghua Cable (Group) Co., Ltd.
Location No.7577 Hunan Road, Pudong New District. Shanghai China
Contact Person Mayling Zhao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.