Characteristics |
Conditions |
Specified values |
Units |
|
|---|---|---|---|---|
|
Optical Characteristics |
||||
|
Attenuation |
1310nm |
≤0.35 |
[dB/km] |
|
|
1383nm(after H2-aging) |
≤0.35 |
[dB/km] |
||
|
1460nm |
≤0.25 |
[dB/km] |
||
|
1550nm |
≤0.21 |
[dB/km] |
||
|
1625nm |
≤0.23 |
[dB/km] |
||
|
Attenuation vs. Wavelength Max. α difference |
1285-1330nm, in reference to 1310nm |
≤0.03 |
[dB/km] |
|
|
1525-1575nm, in reference to 1550nm |
≤0.02 |
[dB/km] |
||
|
Dispersion Coefficient |
1285-1340nm |
-3.5 to 3.5 |
[ps/(nm·km)] |
|
|
1550nm |
≤18 |
[ps/(nm·km)] |
||
|
1625nm |
≤22 |
[ps/(nm·km)] |
||
|
Zero Dispersion Wavelength(λ0) |
-- |
1300-1324 |
[nm] |
|
|
Zero Dispersion Slope(S0) |
-- |
≤0.092 |
[ps/(nm2·km)] |
|
|
Typical Value |
-- |
0.086 |
[ps/(nm2·km)] |
|
|
PMD |
Maximum Individual Fibre |
-- |
≤0.1 |
[ps/√km] |
| Link Design Value(M=20,Q=0.01%) |
-- |
≤0.06 |
[ps/√km] |
|
| Typical Value |
-- |
0.04 |
[ps/√km] |
|
|
Cable Cutoff Wavelength (λCC) |
-- |
≤1260 |
[nm] |
|
|
Mode Field Diameter(MFD) |
1310nm |
8.4-9.2 |
[μm] |
|
|
1550nm |
9.3-10.3 |
[μm] |
||
|
Effective Group Index of Refraction(Neff ) |
1310nm |
1.466 |
-- |
|
|
1550nm |
1.467 |
-- |
||
|
Point Discontinuities |
1310nm |
≤0.05 |
[dB] |
|
|
1550nm |
≤0.05 |
[dB] |
||
|
Geometrical Characteristics |
||||
|
Cladding Diameter |
-- |
125.0±0.7 |
[μm] |
|
|
Cladding Non-Circularity |
-- |
≤0.7 |
[%] |
|
|
Coating Diameter |
-- |
235-245 |
[μm] |
|
|
Coating-Cladding Concentricity Error |
-- |
≤12.0 |
[μm] |
|
|
Coating Non-Circularity |
-- |
≤6.0 |
[%] |
|
|
Core-Cladding Concentricity Error |
-- |
≤0.5 |
[μm] |
|
|
Curl(radius) |
-- |
≥4 |
[m] |
|
|
Delivery Length |
-- |
Up to 50.4 |
[km/reel] |
|
|
Environmental Characteristics |
1310nm, 1550nm & 1625nm |
|||
|
Temperature Dependence Induced Attenuation |
-60℃ to +85℃ |
≤0.05 |
[dB/km] |
|
|
Temperature-Humidity Cycling Induced Attenuation |
-10°C to +85°C, 98% RH |
≤0.05 |
[dB/km] |
|
|
Watersoak Dependence Induced Attenuation |
23°C, for 30 days |
≤0.05 |
[dB/km] |
|
|
Damp Heat Dependence Induced Attenuation |
85°C and 85% RH, for 30 days |
≤0.05 |
[dB/km] |
|
|
Dry Heat Aging |
85℃, for 30 days |
≤0.05 |
[dB/km] |
|
|
Mechanical Specification |
||||
|
Proof Test |
-- |
≥9.0 |
[N] |
|
|
-- |
≥1.0 |
[%] |
||
|
-- |
≥100 |
[kpsi] |
||
|
|
-- |
-- |
-- |
|
|
Macro-bend Induced Loss |
10 Turns Around a Mandrel of 15 mm Radius |
1550nm |
≤0.25 |
[dB] |
| 10 Turns Around a Mandrel of 15 mm Radius |
1625nm |
≤1.0 |
[dB] |
|
| 1 Turn Around a Mandrel of 10 mm Radius |
1550nm |
≤0.75 |
[dB] |
|
| 1 Turn Around a Mandrel of 10 mm Radius |
1625nm |
≤1.5 |
[dB] |
|
|
Coating Strip Force |
typical average force |
1.5 |
[N] |
|
|
peak force |
1.3-8.9 |
[N] |
||
|
Dynamic Fatigue Parameter (nd) |
-- |
≥20 |
-- |
|
YOFC G657A1 EasyBand Bending Insensitive SM Fibre Core Bare Optical Fiber Spool For Optical Cable
Price:
Negotiation
MOQ:
Negotiation
Delivery Time:
3~5 days after get payment
Brand:
YOFC
Product Description
YOFC G657A1 EasyBand Bending Insensitive SM Fibre Core Bare Optical Fiber Spool For Optical Cable
1. What is G657A1 fiber ?
- YOFC EasyBand® bending insensitive single-mode fibre encompasses all the features of FullBand® fibre and provides good resistance to maro-bending.
- It has low macro-bending sensitivity and low water-peak level.
- It is comprehensively optimized for use in O-E-S-C-L band (1260 -1625 nm).
- It offers good resistance to additional losses due to low macro-bending in the 1625 nm wavelength region.
- This not only supports L-band applications but also allows for easy installation without excessive care when storing the fibre, for example, in splicing cassettes.
- For cable use inside buildings, the fibre supports installation with small cable bending radii and compact organizers.
2. Application:
- Short pitch cables for special application
- High performance optical network operating in O-E-S-C-L band
- High speed optical routes in buildings (FTTx)
- Cables with low bending requirements
3. Product standards:
- YOFC EasyBand® bending insensitive single mode fibre meets or exceeds the ITU-T Recommendation G.652.D/G.657.A1 including the IEC 60793-2-50 type B1.3/B6.a1 Optical Fibre Specification.
4. G657A2 Fiber Characterics:
- Low attenuation satisfying the operation demand in O-E-S-C-L band
- Good bending loss resistance at short radius bends
- Low bending loss for highly demanding cable designs including ribbons
- Low PMD satisfying high bit-rate and long distance transmission requirements
- Accurate geometrical parameters that insure low splicing loss and high splicing efficiency
5. Specifications
OEM/ODM Service:
If you want to show your own brand LOGO on the goods such as cable, package bag, label or any where. It is no any problem. Our OEM and ODM service is always ready to do it.
Packing:
According to Stardard Export Packing.
Carton box, wooden box, wooden pallet.
Shipping:
- International express such as UPS, TNT, DHL, etc
- Internatioal air: CA, AA, EA, etc
- By sea
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
KOCENT OPTEC LIMITED
Location
14F, Duocai B Bd, Guanlan Hi-Tech Park, Guanhu, Longhua, Shenzhen, Guangdong, China. P/c : 518110
Contact Person
David He