FTTH Nap Outdoor Fiber Optic Splice Closure / Joint Closure Fiber Optic 16 Cores

Price Negotiable
Price: Negotiable
MOQ: Negotiation
Delivery Time: 5~14 working days
Brand: KCO, Kocent Optec Limited
Product Description
FTTH Nap Outdoor 16Cores Fiber Optic Splitter Splice Closure Junction Box KCO-GJS22 PC+ABS

KCO-1608D Fiber optic splitter closure box is new design to sastify new FTTH demand. It can install 1 pc of 1*8 PLC splitter. Make by high quality PC material, life time is longer.

Features
  • Can accommodate two 1x8 PLC splitter LGX module or steel tube type;
  • Anti-ultraviolet,anti- impact and waterproof function;
  • Unique flip board, flip angle ≥ 180 °, fusion area and distribution area is more obvious, reducing the cable crossing;
  • Fiber optic cable can go in and out of the box without cut the cable.
Specification:
Model KCO-GJS22
Dimension 290*190*110mm
Cable diameter Φ7-φ18mm
Cable port

4pcs round ports

16pcs 2*3mm drop cable ports

Max. Split ratio 2pcs 1x8 mini splitter
Max. Splice tray 1pc
Max. Fusion splice

24 cores

Technical parameters:
  • Optical fiber radius of curvature: ≥40mm
  • Splice tray additional loss: ≤0.1dB
  • Temperature range: -40°C ~ +60°C
  • Anti side pressure: ≥2000N/10cm
  • Impact resistance: ≥20N.m
  • Waterproof level: IP65
Packing list:
Main body 1 set
L=400mm bare fiber buffer tube 2 pcs
Hoop / clamp 2 pcs
3x100 nylon tie 26 pcs
Heat shrinkable tube L=60mm 2-72 pcs (configuration on demand)
User manual 1pc
Product pictures:
Installation way:
Characterictics:
Characteristics Value/Performance Methods and Conditions
Mechanical
Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa.
Remains100kPa±5kPa Measure the internal pressure 24 hours later
Air Tightness after re-installation No air bubble seen and pressure remains unchanged Do re-entry and re-installation 3 times and repeat above Air Tightness Tests.
Axial Pulling Pressure remains unchanged Pulling force: 1000N
Time: 1min
Internal air pressure: 60kPa±5kPa
Compression Pressure remains unchanged Applied pressure: 2000N/100mm
Time: 1min
Internal air pressure: 60kPa±5kPa
Impact Pressure remains unchanged Impact energy: 16N.m
No. of impacts: 3
Internal air pressure: 60±5kPa
Bending Pressure remains unchanged Bending angle±45°(in two opposite directions)
Tension: 150N
No. of bending: 10
Internal air pressure: 60kPa±5kPa
Twisting Pressure remains unchanged Twisting angle: ±90°
Torque: 50N
No. of twisting: 10
Internal air pressure: 60kPa±5kPa
Thermal
Temperature Cycling Pressure drop ≤5kPa Cycling range: -40 ~ +60°C
Cycling time: 2hrs at -40°C, then 2hrs at +60°C
No. of cycling: 3
Internal air pressure: 60kPa±5kPa
Electrical
Insulation Resistance between
metal parts:2.0x105MΩ
Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water.
Resistance between each metal part and ground:2.0x105MΩ
High Voltage No voltage break-downs and sparks Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company KOCENT OPTEC LIMITED
Location 14F, Duocai B Bd, Guanlan Hi-Tech Park, Guanhu, Longhua, Shenzhen, Guangdong, China. P/c : 518110
Contact Person David He

Request A Quote

Please check your email address.
Your message must be at least 20 characters.