Stainless Steel Bending Beam Load Cell Interchangeable With HBK HBM Z6R

Price Negotiable
Price: Negotiable
MOQ: 1pc
Delivery Time: 1-6 weeks
Brand: Forsentek
Product Description

Stainless Steel Bending Beam Load Cell Interchangeable With HBK HBM Z6R

Bending beam load cell FHZR is constructed from stainless steel and hermetically sealed to IP68, it is mechanically and electrically compatible with our model FSH but with a stronger protective shell to withstand harsh industrial working conditions. Beam type load cell FHZR features high accuracy and hygienic design, which makes it applicable for weighing applications in food processing and pharmaceutical industries that involve regular flushing.

load cell HBM Z6R
Specifications

Capacity

20kg 50kg 100kg 200kg

Rated output 2.0 mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.02% of capacity
Hysteresis ±0.02% of capacity
Nonrepeatability ±0.02% of capacity
Creep(30min) ±0.02% of capacity
Safe overload 150% of capacity
Ultimate overload 200% of capacity
Compensated temperature -10...+40oC
Operating temperature -30...+65oC
Temperature shift zero ±0.02% R.O./10oC
Temperature shift span ±0.02% R.O./10oC
Input resistance 380±30 ohms
Output resistance 352±5 ohms
Insulation resistance >5000M ohms
Ingress protection IP68
Material of element Stainless steel
Cable

Ø5.4x3000mm 6-core shielded cable

Wiring code

Blue-Excitation+     Black-Excitation-

Green-Sense+    Grey-Sense-

White-Signal+     Red-Signal-

 

Stainless Steel Bending Beam Load Cell Interchangeable With HBK HBM Z6R

load cell HBK Z6R

A load cell normally contains a wheatstone bridge which produces an output signal proportional to the applied weight or force.The full wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.

Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output of HBM load cell Z6R is around 2mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the output signal range of weighing sensor FHZR is normally within 0...+30mV.

Example: Hermetic load cell FHZR-200kg with 2.0mV/V rated output powered by 5V DC, the output range is 0...+10mV.

HBK load cell Z6R

Click here to download datasheet

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Forsentek Co., Limited
Location 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000
Contact Person Tarik Lu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.