IEC60335-2-113 10mm Thickness Silicone Rubber Artificial Skin
Artificial Skin - Clause 5.102 Of IEC 60335-2-113
IEC 60335-2-113, Household and similar electrical appliances – Safety –
Part 2-113: Particular requirements for beauty care appliances incorporating lasers and intense light sources
5.1 02 Where a test specification requires testing on skin or artificial skin, the artificial skin shall be similar in softness, heat capacity and reflection conditions of human skin
NOTE Suitable material for the artificial skin is silicone rubber with a thickness of 1 0 mm [e.g., (Wacker Chemie AG Elastosil RT 604, A/B) mix ratio = 9:1 with 0,6 % colour (Max Factor Creme Puff Compact Powder – 41 Medium Beige) and 6 % scattering material (Sigma Aldrich Chemical Co. AL203)] 1 .