WUHAN RADARKING ELECTRONICS CORP.
                                                                                                           
Verified Supplier
24 Years
Since 2002
Menu

Industrial Lora Smart Meter 3 Phase Remote ON / OFF Control With Lora Communication

Price Negotiable
Price: Negotiate
MOQ: 50
Delivery Time: 35days
Brand: Radarking
Product Description

Three Phase Lora Smart Meter Industrial Use Smart Meter with Lora Communication

 

 

Main Parameter:

 

Light Coupling Pulse:

 

Constant:

 

Factory setting subject to nameplate
For 1.5(6)A meter:                             Active               6400imp/kW·h
                                                          Reactive           6400imp/kvar·h
For 5(40)A meter:                              Active               600imp/kW·h
                                                          Reactive           600imp/kvar·h
For 5(60)A /15(60)A meter:               Active               400imp/kW·h
                                                          Reactive           400imp/kvar·h
For 20(100)Ameter:                           Active               300imp/kW·h
                                                           Reactive          300imp/kvar·h
 

 

Calendar Clock:

 

Clock Error ≤0.5 s/d                        0℃~+40℃:±2ppm;
                                      -40℃~+85℃: ±3.5ppm
Clock Frequency 1Hz
Battery Life 10 year
Battery Continuous Working Period ≥5 year

 

 

Item   Specification
   
Reference Voltage 3×220V/380V
   
Working Voltage Range 0.8Un~1.15Un
   
Maximum Working Voltage 0.7Un~1.2Un
Reference Current 1.5(6)A 5(40)A 5(60)A 15(60)A 20(100)A
     
Accuracy Active CL 1.0 Reactive CL 2.0
   
Working Temperature -25℃~+60℃
   
Maximum Working Temperature -40℃~+70℃
     

 

 

Features:
 

1. Remote ON/OFF Control
 

2. Metering

 

For active combination, reactive combination 1 and reactive combination 2 power, the valid range is –799999.99~799999.99, and unit is kWh or kvarh.

Positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phase which can be measured. It can set tagged words of active/reactive combination, aim at positive/reverse active power and reactive power in 4 quadrants, to restructure active combination, reactive combination 1 and reactive combination 2.

  • All power can be time-share measured by total and max 4 tariffs. (No time-share measurement for power in A, B, C phases)
  • It can storage power data for 12 settlement period.
  • For positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phases, the valid range is 0~999999.99, and unit is kWh or kvarh

3.  Demand Measurement
 
4. Settlement Function

 

5. Tariff

  • Public holiday can be set, including date and daily period meter number of each public holiday.
  • Weekend holiday can be set, which controlled by tagged word, daily period meter number can also be set for each weekend holiday.

  • If the same for public holiday and weekend holiday, daily period meter number of public holiday will be used.

  • Automatic changeover of century calendar, time, leap year.

  • If tariff number in the period of daily period is larger than tariffs, or the tariffs is 0, the power in the period reckon in tariff 1.

  • It can set solution for 2 time zones, 2 daily periods and switching time (yy/mm/dd/hh/mm) of both two.1st time zone and daily period solution is default selection, when reach switching time of time zone, it changes to 2nd solution of time zone, and when reach switching time of daily period, it changes to 2nd solution of daily period. Then set switching time again for 2 solutions,when reach switching time of time zone, it changes to 1st solution of time zone, and when reach switching time of daily period, it changes to 1st solution of daily period. Switching time would be clear since changes of time zone solution and daily period solution.
  • Max 4 tariffs. Each time zone solution can set 14 time zones as max, with starting time and meter number of daily period which is used. Each daily period solution can set 8 daily periods as max, 14 periods per day, with starting time and tariff which is used. Minimum interval of periods is 15 mins., and period interval is larger than actual demand cycle valve, can be set over 00:00

6. Meter Clear
 
7. Demand Clear
 
8. Event Clear
 
9. Power Freezing
 
10. Security Management & User Authorization
 
11. Warning Function
 
12. Power Off Meter Reading Function
 
13. Clock, Time Function
 
14. Signal Output Function
 
15. Basic Communiction Function
 
16. LCD Display Function

 

 

Notes:
 
No device inside can be adjust by user.
When installing and using, there should be tight enough for each connection line, to avoid from any bad connection which would cause heating to damage the meter. Make sure of the right connection of input and output. Please install the meter on local where is dry and ventilated. Don’t put in the place under direct highlight, especial for infrared window. When using infrared communication, it should take more attention to avoid from any disturb from highlight to infrared interface, and please adjust the distance and angel of infrared, to make sure of reliable communication.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company WUHAN RADARKING ELECTRONICS CORP.
Location No.270, Huangjinkou 3rd Village, Hanyang District, Wuhan City, Hubei Province, China
Contact Person Ada Yang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.