UL1685 Vertical-Tray Fire Propagation Smoke Release Test Equipment for Electrical Fiber Optic Cables SL-7601S
MOQ:
1 Set
Delivery Time:
90 working days after receipt of deposit
Brand:
SKYLINE
Product Description
UL1685 Vertical-Tray Fire Propagation Smoke Release Test Equipment for Electrical Fiber Optic Cables SL-7601S
The SL-7601S is a full-scale fire test system that evaluates the vertical flame propagation and smoke release performance of electrical and optical-fiber cables in compliance with UL 1685-2018 — Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables.
Application Scope
- Determines vertical flame propagation and smoke release of cables and optical-fiber cables under FT4 burning standard
- Test method: cables are bound vertically onto a ladder and ignited; burn height and smoke generation are inspected post-test
Main Technical Parameters
| Chamber internal size (H x L x W) | 3353 x 2438 x 2438 mm |
| Chamber structure | Stainless steel plate with thermal insulation layer, black painted interior |
| Smoke collection tower | 914 mm cubical tower, conical top at 40° |
| Test ladder (tray) | SUS304 ladder 305 (W) x 76 (D) x 2400 (H) mm, rung spacing 25 mm; top steel plate 610 x 610 x 3.2 mm |
| Ignition source | Propane ribbon burner, 341 x 30 mm stainless pan, 242 holes of 1.35 mm in 3 staggered rows (81/80/81) |
| Propane / air flow meter | Mass flow meters, propane 230 mm³/s, air 1330 mm³/s |
| Optical system | Quartz halogen light source (100 W, 12 V DC, 2000-3000 lm) and silicon photocell, optical path 910 mm; light transmittance 0%-100% |
| Exhaust duct | SUS304, 405 mm ID x 5500 mm, straight section 3600 mm |
| Exhaust volume flow | 0.65 ± 0.5 m³/s |
| Bidirectional probe | Range 0-200 Pa, accuracy ±1 Pa |
| Temperature sensor | K-type sheathed thermocouple, 1.5 mm wire diameter (GB/T 16839.1-1997) |
| Control & data acquisition | NI LabVIEW software and Advantech data acquisition card; real-time curves, automatic recording and report printing |
| Power supply | 220 V / 380 V, 50 Hz |
System Composition
Test chamber, smoke collection tower, exhaust duct, ignition source, test ladder, optical measuring system, and data acquisition & processing unit.