SL-FL51 Wires & Cables Smoke Density Test Room

Price Negotiable
Price: negotiated
MOQ: 1 unit
Delivery Time: 20 working days
Brand: SKYLINE
Product Description
IEC61034-1997 Photocell Sensor Wires & Cables Smoke Density Test Room
 
Application
Applies to check the size quantity of producing smoke of cables or optical fiber under prescriptive fire source.
 
Standards
According to  IEC61034-1997, GA306.1-2007, GA306.2-2007.
 
Technical parameters
Burning room size  W3000*D3000*H3000mm (27m3), made of stainless steel
Standard fire source  1.00L±0.01L alcohol
Illuminant nominal power  100w, nominal voltage:DC12v±0.01V
Sensor  photocell, load resistance≤100Ω
Measurement range  0~100%
Alcohol dish  bottom: 210mm×110mm;top:240mm×140mm;height:80mm
Desktop fan  Rotating shaft is 200mm~300mm from found, 500mm±50mm from wall. Fan blades size of 300mm ± 60mm, wind speed:7~15 m3/min
 Min size  100mm×100mm,height: 2150mm

 

What is smoke density?

This test measures the amount of smoke given off by a material that is burning or smoldering. The material is tested when it begins to smolder and again when a flame source is added. The smoke density is between 0 (no smoke generated) and 800. Most finishes and materials require a rating of 450 or less.

 

 