XGN49 SF6 Gas Insulated Switchgear Indoor Gas Insulation Metal-clad Switchgear

 

General Introduction:

XGN49-(12/24)40.5 series indoor gas-insulated metal-clad switchgear(hereinafter called "C-GIS panel") is a switchgear which uses a spring-operated vacuum circuit breaker,electrically operated three station isolation /grounding switch,transformer,lightning arrester as the main components,and completely seals all HV conductors in the metal-clad enclosure with SF6 gas as the insulating medium.

The product has features of flexible combinations,great safety,complete interlocking logic as well as extendibility,miniaturization and free for maintenance.So that it was commonly used in infrastructure construction for power station,power substation,movable transformer pack,rail traffic,buildings that have the 35kV or below nominal voltage.Especially for some sever environment like high altitude,heavy pollution and high humidity.

Installation and Test

The installation foundation construction of C-GIS switchgear shall comply with the relevant provisions in the DL/T5190 technical code for construction and acceptance of electric power construction,and shall be constructed according to the appearance and installation foundation dimensions of the switchgear.The installation foundation drawing and installation splicing diagram of the switchgear are shown below.(Note:If the secondary cables enter the panel from the top,it can be free from equipping the secondary cable hole and cable channel.

 

Parameters Table 

 

Item Unit Parameter
Rated voltage kV 40.5
Rated current A 5~2000
Rated frequency Hz 50
Rated power frequency withstand voltage (1min) Phase to phase, Phase to earth kV 95
Insulation Distance 110
Rated Lightning impulse withstand voltage Phase to phase, Phase to earth kV 185
Insulation Distance 215
1min power frequency withstand voltage of Auxiliary control circuit V 2000
Rated short-circuit breaking current (effective value) kA 20 25 31.5
Rated short-circuit making current(peak time) kA 50 63 80
Rated short time withstand current kA 20 25 31.5
Rated peak withstand current kA 50 63 80
Rated short-circuit keeping time s 4
Degrees of protection   IP67/IP4X
Every phase main return circuit resistance μΩ ≤250
Rated SF6 gas pressure (20°C) Mpa 0.05
Min SF6 gas pressure (20°C) Mpa 0.02
Annual SF6 gas loss rate % ≤1
Rated voltage of auxiliary control circuit V DC110/220,AC220
Dimensions (Width×Depth×Height) mm

(600~1200) ×1400×2650

 

 

Air box Details

 

 

 

SF6 Gas Filling Instruction

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Tianan (Group) Co.,Ltd.
Location 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040
Contact Person Lian Huanhuan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.