IEC60332 Single Wire And Cable Vertical Flame Testing Machine

Price Negotiable
Price: $2150
MOQ: 1PCS
Delivery Time: 7-15 Days
Brand: YUYANG
Product Description

IEC60332 Single Wire And Cable Vertical Flame Testing Machine



Description:


Single Cable Vertical Flame Spread Testing Machine is the most widely used and lower cost of cable fire performance test equipment; It meets the standards IEC 60332-1-1:2004 in the provisions of technical indicators and requirements. Single cable combustion Tester is used to test the flame retardant property of the cable's insulating layer under abnormal conditions such as overheat and over current. It can be used in vertical cable or fiber flame spread test, also can be test the state of flaming droplets during combustion.


Application:


This machine is suitable for the flammability test of various wire and cable insulation covering material PE, PVC and SRPVC. During the test, according to GB/t18380.11-2008 test standard. The two ends of the specimen are fixed and perpendicular to the metal cover of the metal plate. Lighted torch, make the tip of the blue inner cone touch the specimen surface and keep burner and vertical axis 45 °.


Standards:

GB/T 18380.11-2008 Test for combustion of cables and optical cables under flame conditions - Part 11: Vertical flame spread test for single insulated wire and cable

IEC60332-1-1:2004 Tests on electric and optical fibre cables under fire conditions-Test for vertical flame propagation for a single insulated wire or cable.


Specifications:

Combustion chamber
The size of the box body is 300x, 1200 x depth and 450mm
Combustion burner
1KW combustion nozzle (based on GB/t5169.14-2007 / iec60695-11-2:2003 standard), the blue flame height is 50 ~ 60mm, and the total height of the flame is 170 ~ 190mm
Gas
the gas with a high purity of 95%
Sample installation
Sample length: 600-plus / 25mm;
The distance between the upper bracket of two horizontal supports and the upper margin of the lower bracket was 550mm
For fire time
0.1-999.9S continuous setting, the flame can be continuously burnt during the set time.
Installation position of the burner
The upper bracket of the blue flame contact point distance is 475mm, and the vertical axis of the spray lamp and the sample is 45 degree Angle
Control function
manual or automatic
Range of gas flow
100-1000ml/min
Air flow range
1-10l/min
Pressure gauge
0~0.75kpa range adjustment
Ignition mode
High voltage automatic ignition

Advantages:

It is to use a Bunsen burner of a specified size and a specific gas source (propane) to ignite the test sample in a vertical state at a certain flame height and a certain flame application Angle at regular intervals. The flammability and fire hazard of the test sample are evaluated based on the duration of ignition and combustion of the test sample and the length of combustion.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company DONGGUAN YUYANG INSTRUMENT CO., LTD
Location B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Contact Person Yannis Ye

Request A Quote

Please check your email address.
Your message must be at least 20 characters.