YUYANG ISO 9239-1 & ASTM E648 Flooring Radiant Panel Test Apparatus

Price Negotiable
Price: Negotiation
MOQ: 1 set
Delivery Time: 25 work days
Brand: YUYANG
Product Description

YUYANG ISO 9239-1 & ASTM E648 Flooring Radiant Panel Test Apparatus



Description:

Flooring Radiant Panel tester (ISO 9239, Flooring Radiant Panel Tester) is a test method that formally reflect spread of flame on flooring material back- draft condition when fie on building happened in compartment or room adjacent, or high temperature gas radiated to flooring surface a hot radiation heat accumulated at upper of midway during a fire at an early growing step.

Standard:


ISO 9239-1: Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source

ISO 9239-2: Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2

ASTM E 648: Standard Test Method for Critical Radiant Flux of Floor- Covering System Using a Radiant Heat Energy Source


Structure:


1. The structure of the machine consists of two parts: a combustion chamber and a control chamber.

2. Combustion chamber size: about L1420*W1200*H2300 (mm).

3. Control chamber/combustion chamber material: high-quality 304 # stainless steel plate, CNC machine processing.

4. Blowtorch: Fully meet the requirements of GB/T 11785.

5. Other mechanical parts are made of 304 stainless steel or 45# steel, anti-corrosion and anti-rust.


Features:


1. The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature-resistant observation window.

2. The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample.

3. The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen.

4. The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.

5. Dummy calibration specimen with holder, calibrated heat flux meter, and mounting.

6. The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.

7. Heat Flux Meter: Range 0 ~ 50 kW/m2; Surface emissivity: ε=0.95± 0.05.

8. A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.

9. Control Rack for convenience in use, allowing observation of the apparatus and controls during equipment set-up and calibration.

10. It has the function of automatic ignition of the radiant panel and a safety cut-out.


Application range:


The flooring radiant heat flux test device is for paving materials which are placed horizontally and exposed to a slanted heat radiation field with a small flame; various flooring materials such as: textile rugs, cork boards, wood boards, rubber sheets And plastic floor and floor spray materials.


Technical parameters:


 Maximum operating power

 5kw

 Timing accuracy

 <1s / h

 Heat flux meter measuring range

 (0-15) Kw / m2; (heat flow customer-owned)


 Black body temperature error

 ± 5 ℃;

 Smoke speed

 (2.5 ± 0.2) m / s

 Smoke capacity

 (39-85) m3 / min

 Porous refractory radiation board size

 300mm × 450mm, with the ability of about 900 ℃ high temperature;


 Thermocouple

 diameter of 3.2mm K-type stainless steel armored thermocouple

 Burning torch

 diameter ¢ 10mm diameter ¢ 6mm, spray tube on the 35 ¢ 0.7mm hole

 Flame height

 60 ~ 120mm adjustable

 Ignition system

 high voltage electronic ignition

 Burning box size

 L1420 * W1200 * H2300 (mm)

 Strong exhaust system

 The machine is equipped with a strong fan. When the test is completed, start the exhaust fan system


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company DONGGUAN YUYANG INSTRUMENT CO., LTD
Location B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Contact Person Jackson Sun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.