A30 Series Surface Mount Resettable Fuse 9a 30v Current Overload Protection
A30 Series Surface Mount Resettable Fuse 9a 30v Current Overload Protection
A30 Series radial leaded device is designed to provide overcurrent protection for low voltage (≤30V) applications where space is not a concern and resettable protection is preferred.
Cured, flame retardant epoxy polymer insulating
material meets UL 94V-0 requirements
Fast time-to-trip
RoHS compliant, Lead-Free and Halogen-Free*
| Model | V max |
Imax |
I hold |
I trip |
Pd |
Maximum Time To Trip | Resistance | |||
| Current | Time | Rimin | Rimax | R1max | ||||||
| (Vdc) | (A) | (A) | (A) | (W) | (A) | (Sec) | (Ω) | (Ω) | (Ω) | |
| A30-030 | 30 | 40 | 0.30 | 0.60 | 0.44 | 8.00 | 0.30 | 0.300 | 1.100 | 1.600 |
| A30-040 | 30 | 40 | 0.40 | 0.80 | 0.45 | 8.00 | 0.30 | 0.200 | 0.900 | 1.300 |
| A30-050 | 30 | 40 | 0.50 | 1.00 | 0.5 | 2.50 | 4.10 | 0.250 | 0.600 | 1.200 |
| A30-065 | 30 | 40 | 0.65 | 1.30 | 0.47 | 8.00 | 0.40 | 0.200 | 0.500 | 0.800 |
|
A30-070
|
30
|
40
|
0.70
|
0.14
|
0.6
|
3.50
|
4.30
|
0.140
|
0.220
|
0.350
|
|
A30-075
|
30
|
40
|
0.75
|
1.50
|
0.6
|
3.75
|
5.20
|
0.120
|
0.370
|
0.420
|
|
A30-090
|
30
|
40
|
0.90
|
1.80
|
0.6
|
4.50
|
5.90
|
0.070
|
0.220
|
0.300
|
|
A30-110
|
30
|
40
|
1.10
|
2.20
|
0.7
|
5.50
|
6.60
|
0.050
|
0.200
|
0.260
|
|
A30-135
|
30
|
40
|
1.35
|
2.70 |
0.8
|
6.75
|
7.30
|
0.040
|
0.160
|
0.220
|
|
A30-160
|
30
|
40
|
1.60
|
3.20
|
0.9
|
8.00
|
8.00
|
0.030
|
0.140
|
0.180
|
| A30-185 | 30 | 40 | 1.85 | 3.70 | 1.0 | 9.25 | 8.70 | 0.030 | 0.120 | 0.150 |
| A30-250 | 30 | 40 | 2.50 | 5.00 | 1.2 | 12.5 | 10.3 | 0.020 | 0.080 | 0.100 |
| A30-300 | 30 | 40 | 3.00 | 6.00 | 2.0 | 15.0 | 10.8 | 0.020 | 0.070 | 0.100 |
| A30-400 | 30 | 40 | 4.00 |
8.00
|
2.5 | 20.0 | 12.7 | 0.010 | 0.060 | 0.090 |
| A30-500 | 30 | 40 | 5.00 | 10.00 | 3.0 | 25.0 | 14.5 | 0.010 | 0.050 | 0.080 |
| A30-600 | 30 | 40 | 6.00 | 12.00 | 3.5 | 30.0 | 16.0 | 0.005 | 0.040 | 0.060 |
| A30-700 | 30 | 40 | 7.00 | 14.00 | 3.8 | 35.0 | 17.5 | 0.005 | 0.030 | 0.050 |
| A30-800 | 30 | 40 |
8.00
|
16.00 | 4.0 | 40.0 | 18.8 | 0.005 | 0.025 | 0.180 |
| A30-900 | 30 | 40 | 9.00 | 18.00 | 4.2 | 40.0 | 20.0 | 0.005 | 0.020 | 0.025 |
I hold = Hold Current. Maximum current device will not trip in 25°C still air.
I trip = Trip Current. Minimum current at which the device will always trip in 25°C still air.
V max = Maximum operating voltage device can withstand without damage at rated current (Imax).
I max = Maximum fault current device can withstand without damage at rated voltage (V max).
Pd = Power dissipation when device is in the tripped state in 25°C still air environment at rated voltage.
Ri min/max = Minimum/Maximum device resistance prior to tripping at 25°C.
R1max = Maximum device resistance is measured one hour post reflow.
CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.
Q: Can I have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q: Can we have our logo or company name to be printed on your products or the package?
A: Yes, for container order, we have OEM packing service, you need to inform us your logo or company information in details. For bulk cargo, we will use neutral packing.
Q: What adventages do you have?
A: Fast delivery and good service.
Stable quality with competitive price.
Strict management system.
Please tell me:
What product specifications do you need? when you ask for a quotation.I will give you the most competitive price per as your requirements. And we have many types for you to choose.
P.S.:If you can't find any products to meet your requirements. welcome to send us the details drawings so that we can provide us our professional & best service to you.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.