Passthrough Redundant Power Supply Module Emerson DELTAV KJ1501X1-BB1 12P0678X022
Price:
Contact
MOQ:
1
Delivery Time:
3-5days
Brand:
Emerson
Product Description
Emerson DELTAV KJ1501X1-BB1, 12P0678X022 SYSTEM PASSTHROUGH POWER SUPPLY 12/12VDC (DC/DC)
Emerson Fisher-Rosemount
KJ1501X1-BB1
System Power Supply
12VDC
Delta V
Quick Details:
- Place of Origin: California,United States
- Model Number: KJ1501X1-BB1
- Brand Name: Emerson
- Quality: 100% new and origin
- Service: one year warranty
- Terms of quote: Ex-Work
Packaging & Delivery:
new and original factory anti-static bag with individual sealed inner box
Lead Time :within 3 days upon receipt the payment
Shenzhen Wisdomlong Technology CO.,LTD
Contact person:Suki
Email:wtl2502keji@163.com
Skype:wtl2502
Tel:+86-13268302140
I/O Card Redundancy
Redundant I/O cards are available for critical applications. The same card can be used in simplex or redundant applications.When installed on a two-wide redundant terminal block, the cards are recognized as a redundant pair by the controller. The controller scans each card and determines which card is acting
as the active interface. When a fault is detected, the system automatically switches to the standby I/O card.
DeltaV Control modules reference simplex and redundant I/O channels identically and there is no special configuration required to take advantage of redundancy.
Switchover of a redundant I/O card is completed within two scans of the I/O bus. Make-before-break contacts ensure digital field instruments remain powered and the process is undisturbed. Analog output signals are briefly driven by both cards for < 5 ms during switchover of the card.
Hardware Alerts automatically report hardware integrity errors for both the primary and secondary cards. Any event that causes a switchover is also reported automatically through the system hardware alerts and is logged in the Event Chronicle.
Events that can cause a switchover include.
- Hardware failure within the active card.
- Communications failure between the active card and the controller.
- Detection of a fault in the field wiring
A switchover may also be initiated from the diagnostics explorer, and the health and status of both cards and their channels are available in the diagnostics explorer.
The system automatically commissions a new standby card. In safe areas, failed cards can be replaced under power. In hazardous areas, appropriate installation procedures must be followed.
Ordering Information
Analog Input Cards and Termination Blocks
| Description | Model Number |
| 8 Channels 4-20 mA, HART Standard I/O Termination Block | VE4003S2B1 |
| Redundant Standard I/O Termination Block | VE4033S2B1 |
| Fused I/O Termination Block | VE4003S2B2 |
| 4-wire I/O Termination Block | VE4003S2B3 |
| 16-Pin Mass Termination Block | VE4003S2B4 |
| 24-Pin Mass Termination Block | VE4003S2B5 |
| 16 Channels 4-20 mA, HART Standard I/O Termination Block | VE4003S2B6 |
| 4-wire I/O Termination Block 16 Channels 4-20 ma, HART, Plus Card | VE4003S2B7 |
| 16-Channel 2-Wire AI Terminal Block for Series 2 Plus | VE4003S2B9 |
| 16-Channel 4-Wire AI Terminal Block for Series 2 Plus | VE4003S2B10 |
| Redundant 16-Channel 2- & 4-Wire AI Terminal Block for Series 2 Plus | VE4033S2B10 |
| 8 Channels Thermocouple,mV Standard I/O Termination Block | VE4003S4B1 |
| Cold Junction Compensated (CJC) Termination Block | VE4003S5B1 |
|
Analog Input Card: 8 Channels RTD Resistant Temperature Device (RTD) Termination Block |
VE4003S6B1 |
|
Isolated Input Card
Isolated Input Terminal Block
|
VE4003S7B1 |
| Standard I/O Termination Block | VE4005S2B1 |
| Redundant Standard I/O Termination Block | VE4035S2B1 |
| Fused I/O Termination Block | VE4005S2B2 |
| 16-Pin Mass Termination Block | VE4005S2B3 |
| 16-Channel AO Terminal Block for Series 2 Plus | VE4005S2B4 |
| Redundant 16-Channel AO Terminal Block for Series 2 Plus | VE4035S2B4 |
| Standard I/O Termination Block | VE4001S2T1B1 |
| Fused I/O Termination Block | VE4001S2T1B2 |
| Standard I/O Termination Block | VE4001S2T2B1 |
| Redundant Standard I/O Termination Block | VE4031S2T2B1 |
| Fused I/O Termination Block | VE4001S2T2B2 |
| 16-Pin Mass Termination Block | VE4001S2T1B3 |
| 16-Pin Mass Termination Block | VE4001S2T2B3 |
| Standard Termination Block | VE4001S2T2B4 |
| 40-pin Mass Termination Block | VE4001S2T2B5 |
| Redundant32-Channel DI Terminal Block for Series 2 Plus | VE4031S2T2B6 |
| 40-pin DI Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS) | VE4001S2T2B7 |
| 40-pin DI Mass Termination Block for Series 2 Plus including 2 x 16-channel DI Plus Mass Connection Boards* | VE4051S2T2B7 |
| Redundant 40-pin DI Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS) | VE4031S2T2B7 |
| Redundant 40-pin DI Mass Termination Block for Series 2 Plus including 2 x 16-channel DI Plus Mass Connection Boards * | VE4081S2T2B7 |
| Standard I/O Termination Block | VE4001S3T1B1 |
| Fused I/O Termination Block | VE4001S3T1B2 |
| Standard I/O Termination Block | VE4001S3T2B1 |
| Fused I/O Termination Block | VE4001S3T2B2 |
| Discrete 32 Channel Terminal Block | VE4015 |
| Discrete 32-Channel Terminal Block | VE4001S5T2B4 |
| 40-pin Mass Terminal Block | VE4001S5T2B5 |
| Standard I/O Termination Block | VE4002S1T1B1 |
| Fused I/O Termination Block | VE4002S1T1B2 |
| 16-Pin Mass Termination Block | VE4002S1T1B3 |
| Standard I/O Termination Block | VE4002S1T2B1 |
| Redundant Standard I/O Termination Block | VE4032S1T2B1 |
| Fused I/O Termination Block | VE4002S1T2B2 |
| 16-Pin Mass Termination Block | VE4002S1T2B3 |
| 10-Pin Mass Termination Block | VE4002S1T2B4 |
| Standard I/O Termination Block | VE4002S1T2B5 |
| 40-Pin Mass Termination Block | VE4002S1T2B6 |
| 40-pin DO Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS) | VE4002S1T2B8 |
| 40-pin DO Mass Termination Block for Series 2 Plus including 4 x 8-channel DO Mass Connection Boards * | VE4052S1T2B8 |
| Redundant 40-pin DO Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS) | VE4032S1T2B8 |
| Redundant 40-pin DO Mass Termination Block for Series 2 Plus including 4 x 8-channel DO Mass Connection Boards * | VE4082S1T2B8 |
| Standard I/O Termination Block | VE4002S2T1B1 |
| Fused I/O Termination Block | VE4002S2T1B2 |
| Standard I/O Termination Block | VE4002S2T2B1 |
| Fused I/O Termination Block | VE4002S2T2B2 |
| 250V 2A Fuse for Fused Terminal Block; Box of 20 | KJ4010X1-BC1 |
Our advantage Products:
【Honeywell】Module DCS / PLC
【Emerson / Delta V】Module
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【GE/Fanuc】IC69 Series PLC
【Mitsubishi】Servo Drive / Servo Motor
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Wisdomlong Technology CO.,LTD
Location
23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Contact Person
Becky
