Product Description
ABB TU818V1 Compact Module Termination Unit, MTU, 50V 3BSE069209R1 S800 I/O Terminal
Module Termination Units
| Model | Description | Article No. |
| TU805K01 |
TU805K01 Termination Units for two or three wire
connection of DI801 and DO801
Include 10 pcs of Termination Unit TU805 |
3BSE035990R1 |
| TU810V1 |
TU810V1 Compact Module Termination Unit, MTU, 50V.
2x8 signal terminals, rated isol. 50V.
|
3BSE013230R1 |
| TU811V1 |
TU811V1 Compact Module Termination Unit, MTU, 250V.
1x8 signal terminals, rated isol. 250V |
3BSE013231R1 |
| TU812V1 |
TU812V1 Compact Module Termination Unit, MTU, 50V.
With 25 pin D-sub connector, rated isol. 50V. D-sub (female)
connector is not enclosed |
3BSE013232R1 |
| TU813 |
TU813 Compact Module Termination Unit, MTU, 250V
2x8 Signal terminals, Rated isol. 250V Detachable
(pluggable) connectors are enclosed |
3BSE036714R1 |
| TU814V1 |
TU814V1 Compact Module Termination Unit, MTU, 50V.
2x8 Signal terminals, rated isol. 50V. Detachable (pluggable)
connectors are enclosed |
3BSE013233R1 |
| TU818 |
TU818 Compact Module Termination Unit, MTU, 50V
1x32 (and 2x16) signal terminals, Rated isol. 50V
|
3BSE069209R1 |
| TU819 |
TU819 Compact Module Termination Unit, MTU, 50V.
With 2x25 pin D-sub connector, Rated isol. 50V, D-sub
(female) connector is not enclosed |
3BSE068891R1 |
| TU830V1 |
TU830V1 Extended Module Termination Unit, MTU, 50V.
2x16 signal terminals, rated isol. 50V |
3BSE013234R1 |
| TU831V1 |
TU831V1 Extended Module Termination Unit, MTU, 250V.
2x8 signal terminals, rated isol. 250V.
|
3BSE013235R1 |
| TU833 |
TU833 Extended Module Termination Unit, MTU, 50V.
2x16 signal terminals, Rated isol. 50V. Spring-cage
terminals.
|
3BSE038726R1 |
| TU835V1 |
TU835V1 Extended Module Termination Unit, MTU, 50V.
8 fused power outlets, 8 signal terminals, rated isol. 50V |
3BSE013236R1 |
| TU836V1 |
TU836V1 Extended Module Termination Unit, MTU, 250V.
2x4 fused signals, 2x4 return terminals, 2x2 L 2x2N
terminals, rated isol. 250V.
|
3BSE013237R1 |
| TU837V1 |
TU837V1 Extended Module Termination Unit, MTU, 250V.
8x1 fused isol. signals, 8x1 L terminals, 2x6 N terminals,
rated isol. 250V.
|
3BSE013238R1 |
| TU838 |
TU838 Extended Module Termination Unit, MTU, 50V.
2x4 fused transducer power outlets, 16 signal terminals,
2x4 return terminals, 2x2 L+, 2x2 L- terminals, rated isol.
50V. Module is mounted horizontally.
|
3BSE008572R1 |
| TU839 |
TU839 Extended Module Termination Unit, 250V
2x8 signal terminals. 2x4 fused sensor power. Rated isol.
250V
|
3BSE046966R1 |
| TU842 |
TU842 Module Termination Unit, MTU, for redundant
applications, 50V.
Used for AO845, DI840, DO840. Horizontal mounted DIN
rail. Rated isol. 50V.
|
3BSE020850R1 |
| TU843 |
TU843 Module Termination Unit, MTU, for redundant
applications, 50V.
Used for AO845, DI840, DO840. Vertical mounted DIN rail.
Rated isol. 50V.
|
3BSE021443R1 |
| TU844 |
TU844 Module Termination Unit, MTU, for redundant
applications, 50V.
Used with AI845, AI880 and DP840. Horizontal mounted DIN
rail. Rated isol. 50V. Shunt Stick not included.
|
3BSE021445R1 |
| TU845 |
TU845 Module Termination Unit, MTU, for redundant
applications, 50V.
Used with AI845, AI880A and DP840. Vertical mounted DIN
rail. Rated isol. 50V. Shunt Stick not included. |
3BSE021447R1 |
| TU850 |
TU850 Extended Module Termination Unit, MTU, 50V
2x8 signal terminals and 2x8 disconnetable current limited
sensor/transmitter outlet power terminals. Rated isol. 50V. |
3BSE050930R1 |
| TU851 |
TU851 Extended Module Termination Unit, MTU, 250V
2x16 signal terminals, Rated isol. 250V
|
3BSE068782R1 |
| TU852 |
TU852 Module Termination Unit, MTU, for redundant
applications, 50V Horizontal mounted DIN rail, used with redundnat AO, DI,
DO and DP I/O modules, with 2x25 pin D-sub connector, Rated isol. 50V
|
3BSE069964R1 |
| TU854 |
TU854 Module Termination Unit, MTU, for redundant
applications, 50V Horizontal mounted DIN rail, used with redundnat AI and DP I/O modules, with 1x25 pin D-sub connector, Rated isol.
50V, Shunt Stick not included |
3BSE069966R1 |
| TU890 |
TU890 Module Termination Unit for Intrinsic Safety applications
Intrinsic Safety Interface, 3x9 signal terminals Rated isol.
50V
|
3BSC690075R1 |
| TU891 |
TU891 Module Termination Unit for non Intrinsic Safety applications
3x9 signal terminals Rated isol. 50V. |
3BSC840157R1 |
| TY801K01 |
TY801K01 8pcs Shunt Stick TY801
125 + 125 ohms shunt. Used for AI845 and AI880A on
TU844, TU845, TU854 |
3BSE023607R1 |
| TY804K01 |
TY804K01 8pcs Shunt Stick TY804
1000 ohms shunt. Used for DP840 on TU844, TU845, TU854 |
3BSE033670R1 |
| TY805K01 |
TY805K01 8pcs Shunt Stick TY805
125 + 125 ohms shunt with current limitation on transmitter
power. Used for AI845 and AI880A on TU834, TU844, TU845, TU854.
|
3BSE081160R1 |
| TY820K01 |
TY820K01 10pcs Temperature Sensor TY820
TY820 is a temperature sensor with a PT 100 element. Can be used with AI835/AI835A and AI843 to measure cold junction Temperature.
|
3BSE056980R1 |
Module Termination Units and Terminal Units
The Module Termination Units (MTU) are passive base units used to house the I/O modules. They contain the process wiring terminals and a section of the ModuleBus.
The Module Termination Units (MTU) distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configur ations. The configuration can be changed with a screwdriver.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail. The latch can be released with a screwdriver.
The MTU has a mechanical locking mechanism that locks the module in its position. This mechanism also gives the signal BLOCK to the I/O module that keeps the module in its init state until it is locked in its position.
The top part of the MTU can be removed to replace the termination board even with the system running. Such a need can be caused by a damaged terminal screw.
The MTUs are available in tree versions (Compact, Extended and Redundant). The Compact MTU version typically provides for a compact installation of the I/O modules using 1 wire connection.
Picture
Some ABB items sold by WTL:
Liability:
WTL is not liable for any personal injury or property damage resulting from the use of this equipment. It is
buyer's responsibility as to the safe handling & operation of this equipment and to verify equipment is
compliance to their machinery.
Our Brands:
| 【Honeywell】 | Module DCS/PLC/Transmitter |
| 【Emerson/Delta V】 | Module/ CT Motor & Drives |
| 【ABB】 | I/O Module |
| 【AB】 | Module&Touch Screen |
| 【Rosemount】 | Transmitter |
| 【Yokogawa】 | Transmitter |
| 【Yaskawa】 | Servo Drive&Servo Motor |
| 【GE/Fanuc】 | IC69 Series PLC |
| 【Mitsubishi】 | Servo Drive&Servo Motor |
(Modicon,SMC,SICK,NORGREN,Siemens,Ebmpapst etc.)
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Wisdomlong Technology CO.,LTD
Location
23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Contact Person
Becky