Energy Saving Water To Air Heat Pump With LCD Figer Touch Display
Technology Specification
Quick Details
- 1.The heat pump system make up for deficiency of the solar system during cloudy and rainy days
2.Supports all day and all seasons working
3.Extremely compact structure: no copper pipe heat-exchanger in the water tank
4.Water exchanger equipped with high-efficiency tube in shell heat-exchanger
5.Super high-efficiency with automatic defrosting function
6.Safe usage, reliable operating, lower operating cost
7.Intelligent controller and adjustment by quick-mind microprocessor with possibility of remote control
8.Thermostatic heating element for evaporator anti-frosting protection
Feature:
Air Source Heat Pupm Trigeneration System generally can be provided as the following three functions:
1.Air-conditioning cooling in summer. 2. Heating in winter. 3. Domestic hot water provided.
Air Source Heal Pump Trigeneration Units works with fan coil, radianl floor heating and domcslic hoi water supply system. It could take the
advantage and efficiency of heat pump at the best pcrfonnancc and really reach multi-usage, safety, energy saving and comfortable effect.
A. Payment service
1. T/T
2. L/C (for container order only)
B. Technical service
1. We calculate the capacity and recommend the best models.
2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need.
5. We can offer site training to your workers in your place which is negotiable.
C. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One years’warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
ErP Energy label:
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
Packaging & Shipment
1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
| MODEL | Unit | MD10D | |
| Rated heating capacity | KW | 3.5 | |
| Rated Cooling capacity | 1.8 | ||
| Hot water supply | L/h | 75 | |
| Average heating input power | KW | 0.75 | |
| Rated heating input current | A | 6 | |
| Rate outlet water temp | ℃ | 55 | |
| COP | 3.65 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 48 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 1000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 29 | |
| MODEL | Unit | MD15D | |
| Rated heating capacity | KW | 5 | |
| Rated Cooling capacity | 3 | ||
| Hot water supply | L/h | 100 | |
| Average heating input power | KW | 1.25 | |
| Rated heating input current | A | 6 | |
| Rate outlet water temp | ℃ | 55 | |
| COP | 3.65 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 48 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 1600L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 40 | |
| MODEL | Unit | MD20D | |
| Rated heating capacity | KW | 7 | |
| Rated Cooling capacity | 5 | ||
| Hot water supply | L/h | 150 | |
| Average heating input power | KW | 1.84 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 3.8 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A//R410 | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 2000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 55 | |
| MODEL | Unit | MD30D | |
| Rated heating capacity | KW | 12 | |
| Rated Cooling capacity | 7 | ||
| Hot water supply | L/h | 260 | |
| Average heating input power | KW | 3 | |
| Rated heating input current | A | 13/6 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4 | ||
| Power | V/Hz | 220V/380/50 | |
| Noise | Db(a) | 54 | |
| Dimension | W*D*H | mm | 1120*490*710mm |
| Packing size | W*D*H | mm | 1190*520*865mm |
| Unit weight | KG | 108 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 3000L/h | |
| Water pressure down | Kpa | 40 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 100 | |
| MODEL | Unit | MD40D | |
| Rated heating capacity | KW | 16 | |
| Rated Cooling capacity | 10 | ||
| Hot water supply | L/h | 360 | |
| Average heating input power | KW | 4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 160 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 4000L/h | |
| Water pressure down | Kpa | 45 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 125 | |
| MODEL | Unit | MD50D | |
| Rated heating capacity | KW | 18 | |
| Rated Cooling capacity | 12 | ||
| Hot water supply | L/h | 400 | |
| Average heating input power | KW | 4.4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | C | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 160 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 5000L/h | |
| Water pressure down | Kpa | 45 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 150 | |
| MODEL | Unit | MD60D | |
| Rated heating capacity | KW | 21 | |
| Rated Cooling capacity | 15 | ||
| Hot water supply | L/h | 520 | |
| Average heating input power | KW | 5.68 | |
| Rated heating input current | A | 12 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 210 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 6000 | |
| Water pressure down | Kpa | 48 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 175 | |
| MODEL | Unit | MD100D | |
| Rated heating capacity | KW | 36 | |
| Rated Cooling capacity | 24 | ||
| Hot water supply | L/h | 800 | |
| Average heating input power | KW | 9.2 | |
| Rated heating input current | A | 18 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1450×760×1060 |
| Packing size | W*D*H | mm | 1520*800*1230 |
| Unit weight | KG | 289 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 10000L/h | |
| Water pressure down | Kpa | 54 | |
| Pipe size | DN | 32 | |
| Max flat square meter | M2 | 300 | |
| MODEL | Unit | MD150D | |
| Rated heating capacity | KW | 42 | |
| Rated Cooling capacity | 29 | ||
| Hot water supply | L/h | 1200 | |
| Average heating input power | KW | 11 | |
| Rated heating input current | A | 18 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1450×760×1060 |
| Packing size | W*D*H | mm | 1520*800*1230 |
| Unit weight | KG | 320 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 15000L/h | |
| Water pressure down | Kpa | 54 | |
| Pipe size | DN | 32 | |
| Max flat square meter | M2 | 350 | |
| MODEL | Unit | MD200D | |
| Rated heating capacity | KW | 72 | |
| Rated Cooling capacity | 48 | ||
| Hot water supply | L/h | 1590 | |
| Average heating input power | KW | 18.2 | |
| Rated heating input current | A | 35 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.5 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 65 | |
| Dimension | W*D*H | mm | 2040×1100×2000 |
| Packing size | W*D*H | mm | 2080×1150×2130 |
| Unit weight | KG | 650 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 20000L/h | |
| Water pressure down | Kpa | 60 | |
| Pipe size | DN | 50 | |
| Max flat square meter | M2 | 600 | |
| MODEL | Unit | MD300D | |
| Rated heating capacity | KW | 88 | |
| Rated Cooling capacity | 65 | ||
| Hot water supply | L/h | 24000 | |
| Average heating input power | KW | 25 | |
| Rated heating input current | A | 45 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.5 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 68 | |
| Dimension | W*D*H | mm | 2040×1100×2000 |
| Packing size | W*D*H | mm | 2080×1150×2130 |
| Unit weight | KG | 650 | |
| Refrigerant | R417A/R407C | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 30000L/h | |
| Water pressure down | Kpa | 60 | |
| Pipe size | DN | 50 | |
| Max flat square meter | M2 | 730 | |
Air to water source hat pump working principle diagarm
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.