Meeting MD30D Air Source Heat Pump Can Connect Use With Boiler
Meeting MD30D Air Source Heat Pump Can Connect Use With Boiler
Technology Specification
AIR SOURCE HEAT PUMP FEATURE
»Indoor unit mainly includes condenser, 4-way valve and expansion valve.
- Avoid the condenser to be burst in the cold weather, better anti-freezing proctection
- High efficient, lower heat dissipate
» Outdoor unit comprises evaporator, fan and compressor.
- Thermostatic heating element for evaporator anti-frosting protection
- The water connections and the drain pipelines must be protected against frost on site
- compressor outside ,to reduce noise mostly inside the house.
»Auxiliary electronic heater or solar coiler is on your option
» Fashionable design, compact structure, saving the place.
»Quiet, lower the noise when the unit is running
»Advance control panel. Timer function , automatic defrosting function, optional electrical heating, error messages showed for warning.
»It can be work in -25°C low ambient temperature.
Hot water output temperature up to 60°C, for domestic hot water or heating.
auto-defrosting function included. And cooling is optional
A. Payment service
1. T/T
B. Technical service
1. We calculate the capacity and recommend the best models.
2. We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory or online training if you need.
5. We welcome you join us, to be our agent in the whole world.
FAQ
Why us?
1. Timely Delivery, considerate sales after service.
2. 1 Year heat pump warranty, unlimited period for online support.
--You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Top Craftmanship, All products 100% tested.
4. Preferential freight by Famous shipping company.
5. New Design,Very popular style products recommendation for your local market.
Packaging & Shipment
1> Delivery Time : Usually 15 working days after payment
2> Packaging Details :Standard export packing - plywood case with dusty-proof film inside,OEM is acceptable for Factory price.
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order.
5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
| MODEL | Unit | MD10D | |
| Rated heating capacity | KW | 3.5 | |
| Rated Cooling capacity | 1.8 | ||
| Hot water supply | L/h | 75 | |
| Average heating input power | KW | 0.75 | |
| Rated heating input current | A | 6 | |
| Rate outlet water temp | ℃ | 55 | |
| COP | 3.65 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 48 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 1000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 29 | |
| MODEL | Unit | MD15D | |
| Rated heating capacity | KW | 5 | |
| Rated Cooling capacity | 3 | ||
| Hot water supply | L/h | 100 | |
| Average heating input power | KW | 1.25 | |
| Rated heating input current | A | 6 | |
| Rate outlet water temp | ℃ | 55 | |
| COP | 3.65 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 48 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 1600L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 40 | |
| MODEL | Unit | MD20D | |
| Rated heating capacity | KW | 7 | |
| Rated Cooling capacity | 5 | ||
| Hot water supply | L/h | 150 | |
| Average heating input power | KW | 1.84 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 3.8 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 1140×360×540 |
| Packing size | W*D*H | mm | 1200*400*710 |
| Unit weight | KG | 75 | |
| Refrigerant | R417A//R410 | ||
| Working air temp range | ℃ | (-20℃)—45℃ | |
| compressor | Type | Panasonic | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 2000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 20 | |
| Max flat square meter | M2 | 55 | |
| MODEL | Unit | MD30D | |
| Rated heating capacity | KW | 12 | |
| Rated Cooling capacity | 7 | ||
| Hot water supply | L/h | 260 | |
| Average heating input power | KW | 3 | |
| Rated heating input current | A | 13/6 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4 | ||
| Power | V/Hz | 220V/380/50 | |
| Noise | Db(a) | 54 | |
| Dimension | W*D*H | mm | 1120*490*710mm |
| Packing size | W*D*H | mm | 1190*520*865mm |
| Unit weight | KG | 108 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 3000L/h | |
| Water pressure down | Kpa | 40 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 100 | |
| MODEL | Unit | MD40D | |
| Rated heating capacity | KW | 16 | |
| Rated Cooling capacity | 10 | ||
| Hot water supply | L/h | 360 | |
| Average heating input power | KW | 4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 160 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 4000L/h | |
| Water pressure down | Kpa | 45 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 125 | |
| MODEL | Unit | MD50D | |
| Rated heating capacity | KW | 18 | |
| Rated Cooling capacity | 12 | ||
| Hot water supply | L/h | 400 | |
| Average heating input power | KW | 4.4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | C | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 160 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 5000L/h | |
| Water pressure down | Kpa | 45 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 150 | |
| MODEL | Unit | MD60D | |
| Rated heating capacity | KW | 21 | |
| Rated Cooling capacity | 15 | ||
| Hot water supply | L/h | 520 | |
| Average heating input power | KW | 5.68 | |
| Rated heating input current | A | 12 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1120*490*1270 |
| Packing size | W*D*H | mm | 1200*520*1425 |
| Unit weight | KG | 210 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 6000 | |
| Water pressure down | Kpa | 48 | |
| Pipe size | DN | 25 | |
| Max flat square meter | M2 | 175 | |
| MODEL | Unit | MD100D | |
| Rated heating capacity | KW | 36 | |
| Rated Cooling capacity | 24 | ||
| Hot water supply | L/h | 800 | |
| Average heating input power | KW | 9.2 | |
| Rated heating input current | A | 18 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1450×760×1060 |
| Packing size | W*D*H | mm | 1520*800*1230 |
| Unit weight | KG | 289 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 10000L/h | |
| Water pressure down | Kpa | 54 | |
| Pipe size | DN | 32 | |
| Max flat square meter | M2 | 300 | |
| MODEL | Unit | MD150D | |
| Rated heating capacity | KW | 42 | |
| Rated Cooling capacity | 29 | ||
| Hot water supply | L/h | 1200 | |
| Average heating input power | KW | 11 | |
| Rated heating input current | A | 18 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 60 | |
| Dimension | W*D*H | mm | 1450×760×1060 |
| Packing size | W*D*H | mm | 1520*800*1230 |
| Unit weight | KG | 320 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 15000L/h | |
| Water pressure down | Kpa | 54 | |
| Pipe size | DN | 32 | |
| Max flat square meter | M2 | 350 | |
| MODEL | Unit | MD200D | |
| Rated heating capacity | KW | 72 | |
| Rated Cooling capacity | 48 | ||
| Hot water supply | L/h | 1590 | |
| Average heating input power | KW | 18.2 | |
| Rated heating input current | A | 35 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.5 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 65 | |
| Dimension | W*D*H | mm | 2040×1100×2000 |
| Packing size | W*D*H | mm | 2080×1150×2130 |
| Unit weight | KG | 650 | |
| Refrigerant | R417A/R407C/R404A | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 20000L/h | |
| Water pressure down | Kpa | 60 | |
| Pipe size | DN | 50 | |
| Max flat square meter | M2 | 600 | |
| MODEL | Unit | MD300D | |
| Rated heating capacity | KW | 88 | |
| Rated Cooling capacity | 65 | ||
| Hot water supply | L/h | 24000 | |
| Average heating input power | KW | 25 | |
| Rated heating input current | A | 45 | |
| Max outlet water temp | ℃ | 60 | |
| COP | 4.5 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 68 | |
| Dimension | W*D*H | mm | 2040×1100×2000 |
| Packing size | W*D*H | mm | 2080×1150×2130 |
| Unit weight | KG | 650 | |
| Refrigerant | R417A/R407C | ||
| Working air temp range | (-20℃)—45℃ | ||
| compressor | Type | Copeland | |
| Air source heat exchanger | Type | Finned heat exchange | |
| Fan Type | axial flow fan | ||
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 30000L/h | |
| Water pressure down | Kpa | 60 | |
| Pipe size | DN | 50 | |
| Max flat square meter | M2 | 730 | |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.