Dewei Medical Equipment Co., Ltd
                                                                                                           
Verified Supplier
16 Years
Since 2010
Menu

Fast Speed Covid-19 / 2019-NCoV Antigen Rapid Test Cassette Lateral Flow Method 15 Mins

Price Negotiable
Price: $1.8-2.5/pcs
MOQ: 5000pcs
Delivery Time: 3-10 days
Brand: Dewei
Product Description
Individual Package : Fast Speed Covid-19 (2019-nCoV) Antigen Rapid Test Cassette by Swab

 

【INTENDED USE】

The product is used for the qualitative detection of SARS-COV-2 infection. The entire detection process takes only 15-20 minutes, and the operation is simple and sensitive. No instrument required. It can be used for the screening of early infected patients and asymptomatic patients. This method is an effective supplement for nucleic acid detection.

 

【MAIN CONTENTS】

• Rapid Test Cassette.

• Extraction Tube.

• Extraction Buffer.

• Nasal Swab.

• Instructions for use.

• Working Holder.

 

【STORAGE AND STABILITY】

• Store at 39~ 86 º F (4 ~ 30 º C) in the sealed pouch for 18 months.

• Keep away from direct sunlight, moisture and heat.

• DO NOT FREEZE.

 

【DIRECTION OF USE】

1) Add about 10 drops (300µl) of buffer into the extraction tube.

2) Collect the Oral or Nasal sample according to above instruction.

3) Roll the swab at least 6 times while pressing the head against the bottom and side of the extraction tube.

4) Leave the swab into the extraction tube for 1 minute.

5) Squeeze the tube by fingers from outside of the tube to immerse the swab. Remove the swab. The extracted solution will be used as test sample.

6) Put the tip on the tube and tighten up.

7) Add 3 drops (100µl) of the mixed sample to the cassette and read the results in 15 minutes.

 

【INTERPRETATION OF RESULTS】

POSITIVE:

The presence of two lines as control line (C) and test line (T) within the result window indicates a positive result.

NEGATIVE:

The presence of only control line (C) within the result window indicates a

negative result.

INVALID:

If the control line (C) is not visible within the result window after performing the test, the result is considered invalid. Some causes of invalid results are because of not following the directions correctly or the test may have deteriorated beyond the expiration date. It is recommended that the specimen be re-tested using a new test.

 

【PRECAUTIONS】

• For in vitro diagnostic use only.

• Do not use after expiration date.

• The test Cassette should remain in the sealed pouch until use.

• The used test Cassette should be discarded according to local regulations.

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Dewei Medical Equipment Co., Ltd
Location 22E, Bld 06, North Zone, Haining Plaza, Dalang Street, Longhua District, Shenzhen, China
Contact Person Sherry Cai

Request A Quote

Please check your email address.
Your message must be at least 20 characters.