33KV Medium Voltage Instrument Current Transformer Epoxy Resin Casting CE Marked
Epoxy Resin Cast 33KV Medium Voltage Outdoor current instrument transformer
Features
New magnetic material is taken to be the core of the current instrument transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
High precision 0.2s
Designed for 30years lifes
Good Stability in 33kv power line
Big burden.
Multi ratio CT
Theory
Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.
Current transformers are often constructed by passing a single primary turn (either an insulated cable or an uninsulated bus bar) through a well-insulated toroidal core wrapped with many turns of wire. This affords easy implementation on high voltage bushings of grid transformers and other devices by installing the secondary turn core inside high-voltage bushing insulators and using the pass-through conductor as a single turn primary.
Applications
The LZZW3-35Q outdoor current instrument transformers are fully enclosed and cast in epoxy resin. Instrument transformer is equipped with one core and coil assembly rated for measurement and protection, and then output multi ratio. The current transformers are designed for electric power systems of 50Hz/60Hz rated frequency and 35kV rated voltage. They are used for outdoor mounting. The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13. The products are applied to metering electric energy, voltage controlling and relay protection.
1. Measurement current & voltage for energy meter and power meter
2. Supply protection current signal for microcomputer protection relay set
PARAMETERS
TECHNICAL DATA 1: TWO WINDINGS
| Rated primary current(A) | Accuracy class combination | Rated secondary output(VA) | Surface creepage distance (mm) |
Weight(KG) | ||||
|---|---|---|---|---|---|---|---|---|
| 1S/2S | 0.2(S)0.5S | 0.5 | 5P10 | 5P15 | 5P20 | |||
| 10-630 | 0.2(S)/0.5(S) 0.2(S)/5p 0.5(S)/5p |
10 | 20 | 100 | 60 | 40 | 1300 | 90 |
| 750-2000 | 120 | 75 | 50 | |||||
TECHNICAL DATA 2: THREE WINDINGS
| Rated primary current(A) | Accuracy class combination | Rated secondary output(VA) | Surface creepage distance (mm) |
Weight(KG) | ||||
|---|---|---|---|---|---|---|---|---|
| 1s/2s/3s | 0.2(s)0.5S | 0.5 | 5P10 | 5P15 | 5P20 | |||
| 10-500 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5p 0.5(S)/0.5(S)5p |
10 | 20 | 50 | 30 | 25 | 1300 | 90 |
| 600-1000 | 80 | 50 | 30 | |||||
| 1200-2000 | 100 | 60 | 40 | |||||
| 100-630 | 0.2(S)/5p/5p 0.5(S)/5p/5p |
10 | 20 | 30 | 20 | 15 | ||
| 750-1000 | 50 | 30 | 20 | |||||
| 1200-1600 | 60 | 30 | 25 | |||||
| 2000 | 60 | 40 | 25 | |||||
TECHNICAL DATA 3: FOUR WINDINGS SINGLS TRANSFORMAITON RADIO
| Rated primary current(A) | Accuracy class combination | Rated secondary output(VA) | Surface creepage distance (mm) |
Weight(KG) | ||||
|---|---|---|---|---|---|---|---|---|
| 1s/2s/3s/4s | 0.2(s)0.5s | 0.5 | 5P10 | 5P15 | 5P20 | |||
| 10-800 | 0.2(S)/0.2(S)/5P/5P 0.2(S)/0.5(S)/5p/5P 0.5(S)/0.5(S)5p/5P |
10 | 20 | 25 | 15 | 10 | 1300 | 90 |
| 1000 | 30 | 50 | 10 | |||||
| 1200-2000 | 40 | 25 | 15 | |||||
TECHNICAL DATA 4: THREE WINDINGS SINGLS TRANSFORMAITON RADIO
| Rated primary current (A) | Accuracy class combination |
Rated secondary output(VA) | Surface creepage distance (mm) | Wt (KG) |
||||
|---|---|---|---|---|---|---|---|---|
| 1s/2s/3s/4s | 0.2(S)0.5s | 0.5 | 5P10 | 5P15 | 5P20 | |||
| 10-15-20 | 10 | 25 | 10 | 90 | ||||
| 15-20-30 | ||||||||
| 20-30-40 | ||||||||
| 30-40-50 | ||||||||
| 40-50-75 | ||||||||
| 50-75-100 | ||||||||
| 75-100-150 | ||||||||
| 100-150-200 | ||||||||
| 150-200-300 | ||||||||
| 200-300-400 | ||||||||
| 300-400-500 | ||||||||
| 400-500-600 | ||||||||
| 500-600-800 | ||||||||
| 600-800-1200 | ||||||||
| 800-1200-1500 | ||||||||
| 1200-1500-2000 | ||||||||
TECHNICAL DATA 5: IDYN
TECHNICAL DATA 5: IDYN
| Rated primary current (A) | Ith/ls (KA r.m.s.) | Idyn (KA peak) | |
|---|---|---|---|
| Double transformaion ratio | Single transformaion ratio | ||
| 10-15-20 | 10 | 2 | 5 |
| 15-20-30 | 15 | 3 | 7.5 |
| 20-30-40 | 20,25 | 4 | 10 |
| 30-40-50 | 30 | 6.3 | 15.7 |
| 40-50-75 | 40 | 9.4 | 23.6 |
| 50-75-100 | 50 | 12.6 | 31.5 |
| 75-100-150 | 75 | 15.7 | 39 |
| 100-150-200 | 100 | 22 | 55 |
| 150-200-300 | 150 | 31.5 | 78.7 |
| 200-300-400 | 200,250 | 47 | 118 |
| 300-400-500 | 300 | 63 | 157.5 |
| 400-500-600 | 400 | 63 | 157.5 |
| 500-600-800 | 500 | 80 | 200 |
| 600-800-1200 | 600-1200 | 80 | 200 |
| 800-1200-1500 | 1500-2000 | 140 | 200 |
| 1200-1500-2000 | |||
Get in Touch