Three Phase Portable Meter Test Equipment , Portable Test Equipment 0.05% Accuracy
Three Phase Reference Standard Meter Suit for Portable Meter Test Equipment Accuracy 0.05
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
Application
The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.
Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.
FEATURES
- Three phase active or reactive electricity energy meter.
- Calibrate three phase, single phase, and active or reactive meter error.
- Measure U(voltage) of three phase or single phase.
- Measure I(current) of three phase or single phase.
- Measure active power of three phase or single phase.
- Measure reactive power of three phase or single phase.
- Measure apparent power of three phase or single phase.
- Measure power factor of three phase or single phase.
- Measure phase angle between voltage and current.
PARAMETERS
| Electrical parameters | |
| Accuracy class | 0.05%, 0.1% |
| Resolution | 6”TFT (640×480) |
| Power supply | 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz |
| Communication port | RS232 |
| Test voltage | |
| Range | 0-480V |
| Error | ±0.05% (30V-480V) |
| ±0.1% (5V-30V) | |
| Harmonic | 2nd-64st |
| Test current | |
| Range (direct connection) | 5mA-20A |
| Error (direct connection) | ±0.05% (100mA-20A) ±0.1% (10mA-100mA) |
| Range (clamp CT) | 10mA-3000A |
| Error (camp CT) | ±0.2% (100mA-100A) ±0.5% (100A-3000A) |
| Harmonic | 2nd-64st |
| Power measure error | |
| Active power (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) |
| Reactive power (direct connection) | ±0.1% (0.1A-20A) |
| Energy measure error | |
| Active energy (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) |
| Reactive energy (direct connection) | ±0.1% (0.1A-20A) |
| Phase angle | |
| Range | 0o-360o |
| Resolution | 0.01o |
| Error | ±0.05o |
| Frequency | |
| Range | 45-65Hz |
| Resolution | 0.001Hz |
| Error | 0.002Hz |
| Pulse input | |
| Input channel | 2 |
| Input level | 5-24V |
| Input frequency | Max. 2MHz |
| Pulse output | |
| Energy constant | 180000imp/kWh, 1800imp/kWh, 180imp/kWh |
| Pulse ratio | 1:1 |
| Output level | 5V |
| Function | |
| Vector diagram | Yes |
| Waveform | Yes |
| Energy accumulation | Yes |
| Communication with PC | Yes |
| Mechanical parameters | |
| Instrument dimensions (W×H×D) (mm) | 245×162×60 |
| Instrument Weight (kg) | 1.8 |
| Carry case dimensions (W×H×D) (mm) | 450×320×185 |
| Carry case (kg) | 10.6 |
| Environmental conditions | |
| Ambient temperature | -10°C to 55°C |
| Relative humidity | 15%-85% |
Get in Touch