Multi-Phase Secondary Current Injection Protection Relay Test System With Harmonic output
TEST-330 Multi-Phase Secondary Current Injection Protection Relay Test System With Harmonic output
The Test-330 Multi-Phase Secondary Current Injection Protection Relay Test System is the first choice for applications requiring very high accuracy more than 0.1%. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator. It can as a ac or dc current source and voltage, 0-10A, 0-130V accuracy 0.1%.
Its unique accuracy and reliability make the Test-330 ideal for protection and measurement equipment manufacturers for research and development, production and electric power company type testing.
The TEST-330 is a multipurpose, light-weight, field portable test set capable of testing a wide variety of electro-mechanical, solid state and microprocessor-based protective relays, motor overload relays, and similar protective devices.
The unit can be operated either manually via the built-in Keyword, or placed under full computer control via the GFUVE, Advanced Visual Testing Software, or the GFUVE-software running on a PC. In addition, with the open communication architecture, the unit can also be used with third-party software programs such as National Instruments LabVIEW™.
The built-in user interface, called the Smart Touch-View Interface™ (GFUVE), is Megger’s second generation of automatic / semi-automatic manual user interface software. It incorporates a large, easy to read full color, high resolution, high definition, TFT LCD touch-screen display, which displays metered values such as AC and DC Amperes, AC and DC Volts, and Time in both seconds and cycles. Depending on the type of test selected, other values may be displayed, such as Phase Angle, Frequency, Ohms, Watts, VA, or Power Factor.
FEATURES
- Embedded host machine equipped with Complex Programmable Logic Device (CPLD)
- Eight-path synchronous D/A output in a single machine
- High-accuracy linear power amplifier
- Host machine integrated single cabinet structure with big LCD screen and complete interface has obtained appearance patent
- Intelligent self-protection function
- Plentiful Binary and powerful software function
- Easily complete the ABB, Siemens, AREVA, Schneider, GE, SEL, VAMP, Toshiba, NR, Sifang and other foreign manufacturers of protective device test
- Synchronous output of five-phase voltage and three-phase current, Max AC current output is 90A, Max AC voltage output is 260V
- Integrated Smart Touch View Interface.
- Multi-colored graphics with intuitive navigation
- Stand-alone operation, no PC required to operate
- High current output - 90 Amps at 520 VA per phase
- Flexible output design provides up to 10a currents
- Dynamic, Transient and GPS Satellite Synchronized End-to- End Testing Capability
OVERVIEW
- 3 phase current output
- 5 phase voltage output
- 8 binary input, 4 binary output
- Accuracy more than 0.1%
TEST ITEM
- U/I test
- DC test
- Impedance characteristics
- Power direction test
- I-T test
- Differential relay
- Harmonic test
- Differential protection
- Distance protection
- Zero sequence protection
- Setting group test
- State sequence
- Synchronization test
- Special test
- Oscillation test
- Metering instrument
- Hardware checkout
- Low Voltage protection
- Fault Waveform Reproduction
PARAMETERS
| Electrical parameters | |
|---|---|
| Power voltage | AC220V±10% or AC110V±10%, 50/60Hz±10% |
| Time measurement | 0.1ms-999999.999s |
| AC current output | |
| Phase current output (effective value) | 3 x 0-30A |
| Maximum power output | 260VA/phase |
| Maximum parallel current output (effective value) | 0-90A |
| Long-term allowable working value of phase current (effective value) |
>10A |
| Allowable working time of maximum current | >11s |
| Accuracy class | <±0.1% |
| AC voltage output | |
| Phase voltage output (effective value) | 5 x 0-130V |
| Line voltage output (effective value) | 0-260V |
| Maximum power output | 70VA/phase |
| Accuracy class | <±0.1% |
| DC current output | |
| Output range | -10 to 10A or 3 x 0 to ±10A |
| Maximum power output | 200VA |
| Accuracy class | <±0.1% |
| DC voltage output | |
| Output range | 0-300V or 5 x 0 to ±130V |
| Maximum output power | 130VA |
| Accuracy class | <±0.1% |
| Binary input | |
| Idle contact | 1-20mA, 24V (DC) |
| Electric potential contact | 250V/0.5A (DC) |
| Binary output | |
| Idle contact | 250V/0.5A (DC) |
| Rated output | |
| Frequency error | <±0.01Hz |
| Phase error | <±0.1% |
| Waveform distortion | <±0.3% (fundamental wave) |
| Time error | <40µs |
| Output frequency | 0-1050Hz |
| Superposed harmonic wave | 0-21times |
| Mechanical parameters | |
| Dimensions (L×W×H) (mm) | 360x195x375 |
| Weight (kg) | 16.6 |
| Environmental conditions | |
| Use range | 0°C to 45°C |
| Storage range | -25°C to 70°C |