Lab Portable Meter Test Equipment High Accuracy With Automatic Testing PC Software
Three Phase Portable watthour meter test equipment with Automatic testing PC software
The GF302D is a powerful and Three Phase Portable watthour meter test equipment . All test values are generated absolutely synthetically with a high degree of accuracy, low phase shift and stability. The test eqipment is available in 12 A, 24A or 120 A.
The GF302D Three Phase Portable watthour meter test equipment is a lightweight and portable three phase current and voltage source based on newest technology and serves for solving this problem by simulating the required load conditions. Operation is performed by integrated 7“ touch screen or via keyboards.
Watthour meter testing. With the testing requirements of today’s advanced systems, it is essential to take advantage of the new technological features of the Multi-Amp watthour meter test equipment. No matter what size your operation, you will find that Megger offers a range of instruments for watthour meter testing from portable meter testers.
APPLICATION
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.
FEATURES
- Min current output 1mA
- Predefined multiple load points
- Reference meter and power source integration
- User friendly menu guided operation
- Easy verification and analysis of meter installations
- Automatic operation without need of an external PC
- Generation of harmonics in current and voltage up to the 51th
- Verification of the load conditions on metering installation
- Verification of the energy registration
- Automatic testing mechanical meter and electronic meter error
- Voltage, current, frequency, phase angle, power factor, harmonics can be regulated
- 1P2W, 1P3W, 3P3W, 3P4W can be set
- 4 quadrant measurement
- Vector diagram display and phase sequence indication on integrated colored screen
- Especially configured USB stick for storage of customer data and measurement results
PARAMETERS
| Electrical parameters | |
|---|---|
| Accuracy | 0.02%, 0.05%, 0.1% |
| Power Supply | Single phase AC 85-265V, frequency 50/60Hz. |
| AC Voltage Output | |
| Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional); max 500V |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.2% (Non-capacitive load) |
| Output load | each phase 25VA |
| Accuracy | 0.05%RG or 0.02%RG |
| AC Current Output | |
| Range(I1,I2,I3) | 200mA, 1A, 5A, 20A; max 25A |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s |
| Distortion | ≤0.2% (Non-capacitive load) |
| Output load | 25VA |
| Accuracy | 0.05%RG or 0.02%RG |
| Power Output | |
| Active power output stability | <0.01%RG/120s |
| Reactive power output stability | <0.02%RG/120s |
| Active power measuring accuracy | 0.05%RG or 0.02%RG |
| Reactive power measuring accuracy | 0.1%RG |
| Phase Output | |
| Output adjustment range | 0°-359.999° |
| Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
| Resolution | 0.01° |
| Accuracy | 0.02° |
| Power Factor | |
| Adjustment range | -1 ~ 0 ~ 1 |
| Resolution | 0.0001 |
| Measurement accuracy | 0. 0005 |
| Frequency Output | |
| Adjustment range | 40Hz-70Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.002Hz |
| Voltage /Current/Harmonic Setting Output | |
| Harmonic number | 2-51times |
| Harmonic content | 0-40% |
| Harmonic phase | 0-359.99 |
| Harmonic setting accuracy | (10%±0.1%)RD(2) |
| Power Energy Measurement Error | |
| Active power energy | 0.05%RG or 0.02%RG |
| Reactive power energy | 0.1%RG |
| Power Pulse Output | |
| Power pulse type | active pulse, reactive pulse |
| Active power pulse output | 5V, 10mA |
| Power Pulse Input | |
| Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
| Communication Port | |
| Communication Port | RS232, USB2.0 |
| Safety | |
| Isolation protection | IEC 61010-1:2001 |
| Measurement Category | 300 V CAT III, 600 V CAT II |
| Degree of protection | IP20 |
| Declaration of conformity | CE certified |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 445x460x158 |
| Weight (kg) | 18 |
| (1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
|
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.