240a 600v Three Phase Portable Meter Test Equipment Harmonic Analysis Function
0.02% 240A 600V Three Phase Reference Standard Meter Using In Metrology Laboratory of Utility or Nation Measurement Lab
Model: GF333V2
● High accuracy up to 0.01%
● Test type: 3 phase 4 wire, 3 phase 3 wire
● Wide testing range: voltage:5V ~ 480V, current: 1mA ~ 120A
● Test mode: active power, reactive power, cross connected reactive power
● Waveform display function
● Harmonic analysis function
● Energy accumulating function
● Vector diagram function
● Test data can be managed by computer via Rs232 interface
Applications
● Nation-level utility companies
● Governmental bureaus of metrology
● Big energy meter manufacturers
● Primary Competitive Advantages:
● High quality product
● High Accuracy up to 0.01%
● High stability
● Friendly interface
● Convenient operation
● Product Tags: Electrical Test Instrument Standard Electric Meter
Features
● Wide testing range: voltage: 1V...600V, current: 1mA...240A
● Testing type: 3 phase 4 wire, 3 phase 3 wire
● Testing mode: active power,reactive power,cross connected reactive power and apparent power.
● Measuring voltage, current, phase angle, frequency, power, energy(kWH) etc of each phase
● Measuring phase angle of phase to phase, sum of active power, sum of reactive power , sum of apparent power etc
● Harmonic analysis function
● Waveform display function
● Vector diagram function
● Energy accumulating function
● Internal pulse input port, testing meter's error directly.

Technical parameters
| Test Voltage | |
| Range | 1V – 600V |
| Error |
±0.01% (30V – 600V) ±0.03% (5V – 50V) |
| Display range | 5.000000V – 600.0000V |
| Test Current | |
| Range | 1mA – 240A |
| Error |
±0.01% (0.2A – 240A) ±0.05% (1mA – 0.2A) |
| Display range | 1.000000mA-120.0000A |
| Power measure error | |
| Active power | ±0.01% (0.2A – 240A) ±0.02% (0.01A – 0.2A) ±0.05% (1mA – 0.01A) |
| Reactive power | ±0.05% (0.2A – 240A) ±0.1% (1mA – 0.2A) |
| Apparent power | ±0.05% (0.2A – 240A) ±0.1% (1mA – 0.2A) |
| Energy measure error | |
| Active energy | ±0.01% (0.2A – 240A) ±0.02% (0.01A – 0.2A) ±0.05% (1mA – 0.01A) |
| Reactive energy | ±0.05% (0.2A – 240A) ±0.1% (1mA – 0.2A) |
| Apparent energy | ±0.05% (0.2A – 240A) ±0.1% (1mA – 0.2A) |
| Phase angle | |
| Range | 0º – 360º |
| Error | ±0.002º |
| Display range | 0.000001º -- 359.9999º |
| Frequency | |
| Range | 45Hz – 65Hz |
| Display range | 45.0000 – 65.0000 |
| Pulse output | |
| High frequency output(CH) |
1×1012 (1mA – 2mA) 1×1011 (2mA – 20mA) 1×1010 (20mA – 0.2A) 1×109 (0.2A – 2A) 1×108 (2A – 20A) 1×107 (20A – 240A) |
| Low frequency output(CL) | 2×10-5×CH |
| Pulse ratio | 1:1 |
| Output level | 5V |
| Pulse input | |
| Input level | 5V |
| Input frequency | Max. 1MHz |
| Other | |
| Voltage Supply | 220V ± 10%, 50/60Hz ± 2Hz |
| Ambient temperature | 10°C -- 30°C |
| Influence of external fields | ≤ 0.05 % / mT |
| Relative humidity | 45% -- 75% |
| Dimensions (W×H×D) (mm) | 445×260×300 |
| Weight (kg) | 7.5 |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.