GF312B Onsite Portable Three Phase Energy Meter Calibrator with Printer Testing Equipment

 

GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line. It can measure wave distortion factor and 2nd to 63th harmonic wave.

 

Features

  1. Three phase active or reactive electricity energy meter
  2. Calibrate three phase, single phase, active or reactive meter error
  3. Measure U(voltage) of three phase or single phase
  4. Measure I(current) of three phase or single phase
  5. Measure active power of three phase or single phase
  6. Measure reactive power of three phase or single phase
  7. Measure apparent power of three phase or single phase
  8. Measure power factor of three phase or single phase
  9. Measure phase angle between voltage and current
  10. Measure frequency of power line
  11. Display vector diagram
  12. Display waveform of U and I
  13. Analyze and display content of harmonic of U and I
  14. Store and check measured data
  15. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp
  16. Measure CT variable ratio
  17. Print the data of measurement on site

Parameters

 

Electrical parameters  
Accuracy class 0.05, 0.1%, 0.2%
Power supply 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz
Test Voltage  
Range 0V-600V
Error ±0.05% (30V-600V)
±0.1% (5V-30V)
Harmonic 2nd-63st
Test Current  
Range (direct connection) 20mA-20A
Error (direct connection) ±0.05% (100mA-20A)
±0.1% (20mA-100mA)
Range (Clamp CT) 10mA-3000A
Error (Clamp CT) ±0.2% (100mA-3000A)
±0.5% (10mA-100mA)
Harmonic 2nd-63st
Power measure error  
Active power (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-20A)
Energy measure error  
Active energy (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-20A)
Phase angle  
Range 0o ~ 360o
Resolution 0.01o
Error ±0.05o
Frequency  
Range 45Hz-65Hz
Resolution 0.001Hz
Accuracy 0.005Hz
Power factor  
Range -1 ~ 0 ~ 1
Resolution 0.0001
Error 0. 0005
Pulse output  
Energy constant 180000imp/kWh, 1800imp/kWh, 18imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse input  
Input channel 1
Input level 5-24V
Input frequency Max. 2MHz
Display  
Resolution 6”TFT (640×480)
Function  
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication port RS232
Communication with PC Yes
Mechanical parameters  
Dimensions (W×H×D) (mm) 390×200×160
Host Weight (mm) 3
Weight (including Accessories 3pcs 100A clamp CT) (kg) 12
Environmental conditions  
Ambient temperature -10°C to 40°C
Relative humidity 30%-85%

 

Photo

 

 

 

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Location Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Contact Person Andy

Request A Quote

Please check your email address.
Your message must be at least 20 characters.