1P2W Synchronous Electrical Power Calibrator Creep Testing
Price:
USD12000-15000/SET
MOQ:
3sets
Delivery Time:
1-2WEEKS
Brand:
GFUVE
Product Description
INTRODUCTION
GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.
FEATURES
- Meter under testing: 1P2W
- Testing mode: active power, reactive power
- Test 3pcs or 2pcs meter synchronously
- Start testing and creep testing
- Reference standard and power source integrated, easy to carry
- Measuring mechanical meter and electric meter
- Operating by manual keyboard or PC software
- With keyboard shortcuts
- Internal large capacity storage device for mass memory
- Local checking the testing result
- Overload, short circuit, open circuit protection
- With self-checking function
- TECHNICAL PARAMETERS
-
Electrical parameters Accuracy class 0.05%, 0.1% Power supply One Phase AC 100-265V, frequency 50/60Hz. AC Voltage Output Range 57.7V, 100V, 220V, 380V; max 500V Adjustment range (0-120)%RG(1) Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Distortion 0.1% (Non-capacitive load) Output load max 25VA Measuring accuracy 0.05%RG AC Current Output Range 200mA, 1A, 5A, 20A, 100A; max 120A Adjustment range (0-120)%RG Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability <0.01%/120s Distortion ≤0.1% (Non-capacitive load) Output load max 50VA Accuracy 0.05%RG Power Output Active power output stability <0.01%RG/120s Reactive power output stability <0.02%RG/120s Active power measuring accuracy 0.05%RG Reactive power measuring accuracy 0.1%RG Phase Output Output adjustment range 0°-359.999° Output adjustment fineness 10, 1, 0.1, 0.01 as optional. Resolution 0.01° Accuracy 0.05° Power Factor Adjustment range -1 ~ 0 ~ 1 Resolution 0.0001 Measurement accuracy 0. 0005 Frequency Output Adjustment range 40Hz-70Hz Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. Resolution 0.001Hz Accuracy 0.005Hz Voltage /Current/Harmonic Setting Harmonic number 2-51times Harmonic content 0-40% Harmonic phase 0-359.99 Harmonic setting accuracy (10%±0.1%)RD(2) Power Energy Measurement Error Active power energy 0.05%RG Reactive power energy 0.1%RG Power Pulse Output Power pulse type active pulse, reactive pulse Active power pulse output 5V,10mA Power Pulse Input Energy pulse type support active and reactive pulse, the highest frequency
power pulse input is 180K.Mechanical parameters Dimensions (W×D×H) (mm) 455x440x150 Weight (kg) 12 Environmental conditions Ambient temperature -10°C to +40°C Relative humidity 35%-85%
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Location
Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Contact Person
Andy