Single point Load Cell IPW6C Capacity 3-40kg Static Weighing Aluminum weight force sensor 2mv/v C3 C6 for Counting Scale IP67
IPW6C 3KG TO 40kg single point load cell aluminum material for Static Weighing OIML C3 C6
40kg Counting Scale Portable Load Cell Sensor For Weight Measurement ODM
-- Accuracy class C3 with OIML-R60 test report
-- Off center load compensated (OIML R 76)
-- Max. capacities: 3 kg ... 40 kg
-- Degree of protection IP67(according to EN 60 529)
-- Shielded connection cable
-- Optimized for static weighing applications
-- Accuracy class C6 with OIML-R60 test report
-- Connection cable in six wire circuit
-- Different cable lengths
− Aligned output, suitable for connectionin parallel
| Type | IPW6C | ||||||||
| Accuracy class1) | C3; C3MR | ||||||||
| Number of load cell intervals (nLC) | 3000 | ||||||||
| Maximum capacity (Emax)2)) | kg | 3 | 5 | 10 | 15 | 20 | 30- | 40 | |
|
Minimum LC verification interval (vmin) Accuracy class C3 |
g | 10 | 10 | 20 | 20 | 50 | 50 | 50 | |
|
Temperature effect on zero balance (TK0) Accuracy class C3
|
% v. Cn / 10 K
|
±0.0233 | ±0.0280 | ±0.0280 | ±0.0186 | ±0.0350 | ±0.0233 | ±0.0350 | |
|
Minimum LC verification interval (vmin) Accuracy class C3MR |
g | 0.2 | 0.5 | 1 | 1 | 2 | 2 | 5 | |
|
Temperature effect on zero balance (TK0) Accuracy class C3MR |
% v. Cn / 10 K
|
±0.0093 | ±0.0140 | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0093 | ±0.0175 | |
| Max. platform size | mm | 300 x 300 | |||||||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | |||||||
| Zero balance | 0±0.12 | ||||||||
|
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] |
% v. Cn / 10 K
|
±0.0175 ±0.0117 |
|||||||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||||
| Non-linearity (dlin)3) | ±0.0166 | ||||||||
| Minimum dead load output return (DR) | ±0.0245 | ||||||||
| Off center load error4) | ±0.0233 | ||||||||
| Input resistance (RLC) | Ω | 300 ... 500 | |||||||
| Output resistance (R0) | 300 ... 500 | ||||||||
| Reference excitation voltage (Uref) | V | 5 | |||||||
| Nominal range of excitation voltage (BU) | 1...12 | ||||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||||
| Nominal temp. range (BT) |
°C [°F] |
−10 ... +40 [+14 ... +104] | |||||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||||
|
Safe load limit (EL ), at max. 100mm eccentricity |
% of Emax |
150 100 |
|||||||
| Lateral load limit (Elq), static |
% of Emax |
300 | |||||||
| Breaking load (Ed) | 300 | ||||||||
| Deflection at Emax (snom), approx. | mm | < 0.5 | |||||||
| Weight (G), approx. | kg | 0.25 | |||||||
|
Protection class according to EN 60 529 (IEC 529) |
IP67 | ||||||||
|
Material: Measuring element Coating Cable sheath |
Aluminum Silicone rubber PVC |
||||||||





Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.