Fire Resistant Oil Purifier Machine for EH Oil & Phosphate Ester Oil Treatment
NSH FV Series High Efficiency Fire Resistance Oil Purifier is especially designed for fire-resistant oil with suitable material for vacuum dehydration, particles-removal and acid-reduction.
For customer choice, we also have a simple type to purify fire-resistant oil: High precision oil filtration. It has simple structure with multi-stage filters to remove particles to NAS grade 5. The function of this machine is to filtrate impurities and particles from fire-resistant oil, but cannot remove water. It is suitable for the occassions where cleanliness is important and water content is not required.
- The tank and pipelines where fire-resistant oil going through are all made of stainless steel.
- Dehydrate by vacuum dehydration, water content less than 100ppm.
- Oil-input and oil-output keep balance by photoelectric switch which is sensitive and accurate to monitor oil level in the tank, stop inputting oil when level marked high and keep inputting oil when low.
- We use filters which designed only for fire-resistant oil to remove particles. Cleanliness up to NAS grade 5.
- There is system with absorbent to solve acid problem.
- After treatment, the important index-resistivity up to ≥ 6 x 109.
- Good appearance, compact structure and easy operation.
| Parameter | Before | After |
|---|---|---|
| Water Content | 1200 ppm | ≤100 ppm |
| Cleanliness | NAS 10 | NAS 5 |
| Acid Value | 0.25 mgKOH/g | 0.05 mgKOH/g |
| Resistivity | Low | ≥6×10⁹ Ω·cm |
- Fixing type,mobile type with four wheels and mobile type with trailer.
- Normal appearance type,shelf-covering type and explosion-proof type.
- Avaliable in different color.
| Item | Unit | FV-10 | FV-20 | FV-30 | FV-50 | FV-100 | FV-150 | FV-200 | |
| Flow Rate | L/H | 600 | 1200 | 1800 | 3000 | 6000 | 9000 | 12000 | |
| Vacuum Range | Mpa | -0.065 ~ -0.096 | |||||||
| Working Pressure | Mpa | ≤ 0.4 | |||||||
| Clearness | NAS | ≤ 6 | |||||||
| Temperature Range | °C | 40 ~ 80 | |||||||
| Water Content | PPM | ≤ 100 | |||||||
| Impurity Size | μ m | ≤ 5 | |||||||
| Power Supply | V | 380V/50Hz(or as needed) | |||||||
| Working Noise | dB | ≤ 70 | ≤ 75 | ||||||
| Heating Power | Kw | 15 | 18 | 30 | 45 | 90 | 120 | 180 | |
| Total Power | Kw | 17 | 21 | 33 | 48 | 95 | 126 | 187 | |
| Pipeline Diameter | mm | DN20 | DN20 | DN20 | DN25 | DN32 | DN40 | DN50 | |
| Net Weight | Kg | 360 | 430 | 550 | 750 | 950 | 1050 | 1200 | |
| Size | length | mm | 1300 | 1350 | 1400 | 1500 | 1650 | 1750 | 1850 |
| width | mm | 900 | 950 | 1000 | 1200 | 1300 | 1400 | 1500 | |
| high | mm | 1700 | 1750 | 1800 | 1850 | 1900 | 2000 | 2050 | |
- ✅ Water content reduced to ≤100 ppm
- ✅ Cleanliness up to NAS Grade 5
- ✅ Acid removal system included
- ✅ Stainless steel pipeline design
- ✅ Suitable for EH oil and phosphate ester oil
- ✅ Mobile and explosion-proof versions available
- VFD series: Insulation oil purifier System specialize in purifying branded oil, insulation oil of high voltage and super high voltage transformer. Additionally, it is suitable for treating low viscosity lubrication oil.
- TF series: Turbine oil purifier system is particularly suitable for purifying turbine lubricating oil. It also applys to treat hydraulic, coolant oil and other lubrication in which contain large of water, vapor, impurities, sludge, dielectric and colloid. It can eliminate them effectively and efficiently.
- LV series: Lubrication Oil Filter System are suitable especially for purifying and restoring hydraulic oil, machine oil, coolant oil and various other lubrication oil.
- GER series: Used oil regeneration system is suitable to regenerate used internal-combustion engine oil including diesel engine oil, gasoline engine oil, and used hydraulic oil, other used lubrication oil of machinery.
- GED series: it is used to recycle all kinds of waste oil into base oil or diesel oil with high quality.

Project: 600MW Thermal Power Plant
Location: Indonesia
Oil Type: EH Fire Resistant Oil
Problem:
- Water contamination
- High acid value
Result:
- Water reduced from 850ppm to 60ppm
- NAS cleanliness improved to Grade 5
- Turbine system returned to operation
Application industries
- Power Plant EH Oil System
- Steel Plant Hydraulic Station
- Petrochemical Industry
- Turbine Lubrication System
Get in Touch