PS16E Series Up To 2000Amp OLED Display Closed Loop Resistance And Inductive Load Single Phase Thyristor Power Regulator
 
 
PS16E Series Up To 2000Amp OLED Display Closed Loop Resistance And Inductive Load Single Phase Thyristor Power Regulator is widely used in resistance and inductive Load heating control.
 
 
Features
1. Lightweight, compact mounted three phase thyristor regulator
2. The standard OLED digital setter can read and set the internal function parameters of the regulator (voltage, current, power, load impedance and each function parameter)
3. The phase control mode and the zero position control mode can be switched by the setter (in which the zero position control mode is divided into variable period zero crossing trigger and fixed period zero crossing trigger)
4. The new zero-crossing trigger with fixed period can control the inductive load and the primary side of transformer.
5.The voltage / current feedback / power feedback type can be selected (specify one) when the phase control mode is adopted.
6. Can add Modbus communication function, can be a variety of set values and voltage and current power and other parameters read to the upper computer
7. Selection of five input signal types (contact signal DC4--20mA, DC1--5V, DC 0--5V, DC 0--10V)
8. Rated current: 30A 50A 80A 100A 200A 250A 300A 400A 500A 1000A 1500A 2000A
9. Rated voltage: AC220V / AC380V

 
Specification
 

Phase numberSingle phase
Control modePhase control mode (phase shift trigger)
Zero position control mode (variable period zero crossing trigger)
FeedbackNo feedback, voltage feedback, current feedback, power feedback (when a feedback mode is specified for phase control)
Rated voltageAC 220V/ AC 380V
Allowable voltage change±10% of Rated voltage
Rated frequency50/60Hz
Allowable frequency changeRated frequency ±1Hz
Rated current30A,50A,80A,100A,150A,200A,250A,300A,400A,500A,600A,800A,1000A,1500A,2000A
Input SignalDC 4--20mA input impedance: 120Ω
DC 1--5V input impedance: 10k Ω
DC 0-- 5V input impedance: 10k Ω
DC 0--10V input impedance: 10k Ω
Output RangeNo feedback, 0-- 98% output range of rated voltage
Voltage feedback, 0-- 98% output range of rated voltage
Current feedback, 0-- 100% output range of rated voltage
Power feedback, 0-- 98% output range of rated voltage*0-- 100% output range of rated current
Output PrecisionNo feedback, rated voltage±10%
Voltage feedback, rated voltage±3%
Current feedback, rated voltage±3%
Power feedback, rated power±3%
Load TypeResistive load (phase shift trigger, Variable period zero crossing trigger)
Inductive load (phase shift trigger)
Minimum load current0.5A above (98% output of rated voltage)
Other functionSoft start, soft off(0--60S),Operation stop switch, external setters (slope, base point, manual, etc.) overcurrent protection, overvoltage protection, current limit, voltage limit
Alarm action1. Overcurrent alarm: ALM alarm light, alarm parameters display, alarm contact output
2. Overvoltage alarm: ALM alarm light, alarm parameters display, alarm contact output
3. Load breakage alarm Alm alarm lamp on, alarm parameters display, alarm contact output
4. Radiator overtemperature alarm: Alm alarm light on, alarm parameter display, alarm contact output
Alarm output numberOne point
Alarm contact capacityAC250V 3A
Cooling modeRated current 30A (including 30A) below self-cooling
Rated current 50 A (including 50 A) above air cooling
Output setting rangeSlope setting (internal), 0~100% of output range
Operating ambient temperature-10℃--55℃
Operating environment humidity30%RH--90%RH
Insulation impedanceDC 500V,20MΩ
Insulation strengthAC 2000V/min
Materials and CoatingsPlate / spray coating

 
Communication
 

Communication protocolModbus RTU(optional)
Communication interfaceRS485
Baud rate4800bps 9600bps 19200bps

 
Setting unit
 

Setting item1. Run (run / stop) output mode (automatic / manual)
2. Control mode (phase control / zero control)
3. Feedback type (no feedback / voltage feedback / current feedback / power feedback)
4. Manual output value (0 / 100%) slope setting (0 / 100%)
5. Current limit value (0 ~ 100% rated current) voltage limit value (0 ~ 100% rated voltage)
6. Over-current protection (on / off) overcurrent protection value (1.2 times rated current)
7. Over-voltage protection (on / off) overvoltage protection value (1.2 times rated voltage)
8. Soft start time (0 ~ 60s) soft turn-off time (0 ~ 60s)
9. Load off alarm (on / off)
10. Communication address, communication rate, communication parity check, host computer control (on / off)
11. Fixed period zero crossing control feedback (on / off)
Display itemVoltage value, current value, power value, load impedance value, input signal percentage, alarm code, various set values, various states
Digital DisplayOLED display (display resolution 128 × 64) measurement value, set value, alarm value, etc.
Status Display4 LED status lights (red, green) running state, manual state, stop state, alarm state

 
Shipment and Packaging

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Noker Electric Co.,Ltd.
Location 33 North Street, High-tech Industry Development Zone, Xi 'an City, Shaanxi Province, China.

Request A Quote

Please check your email address.
Your message must be at least 20 characters.