BS476 Tested Fire Rated Wooden Doors
Our fire rated wooden doors are tested to BS476:part22 standard with fire ratings of 30, 60, and 90 minutes. These 50mm thick doors feature HPL finish and are designed for hotel applications with various color options.
Technical Specifications
Construction
Door frame uses fire retardant Chinese fir with 8mm fire board facing. Door leaf contains fire-retardant skeleton with environment-friendly pertile fire board filling.
Performance
Withstands temperatures up to 1000°C. Features fireproof and smoke resistant expansion sealing strips that activate during fire conditions.
Surface Finish
Melamine veneer decorative surface provides high compressive strength and scratch resistance, suitable for demanding construction environments.
Standard Structural Openings
Single Opening Sizes
0618, 0620, 0820, 0821, 0824, 0920, 0921, 0924, 1020, 1021, 1023
Double Opening Sizes
1220, 1221, 1223, 1520, 1521, 1523, 1820, 1821, 1823, 2020, 2021
Fire Resistance Rating Classification
Door Type Fire Resistance Performance Code
Fully Heat Insulated Doorsets (Class A) Fire Insulation ≥0.50h Fire Integrity ≥0.50h A0.50 (Grade C)
Fire Insulation ≥1.00h Fire Integrity ≥1.00h A1.00 (Grade B)
Fire Insulation ≥1.50h Fire Integrity ≥1.50h A1.50 (Grade A)
Fire Insulation ≥2.00h Fire Integrity ≥2.00h A2.00
Fire Insulation ≥3.00h Fire Integrity ≥3.00h A3.00
Partially Heat Insulated Doorsets (Class B) Fire Insulation ≥0.50h | Fire Integrity ≥1.00h B1.00
Fire Integrity ≥1.50h B1.50
Fire Integrity ≥2.00h B2.00
Fire Integrity ≥3.00h B3.00
No Heat Insulated Doorsets (Class C) Fire Integrity ≥1.00h C1.00
Fire Integrity ≥1.50h C1.50
Fire Integrity ≥2.00h C2.00
Fire Integrity ≥3.00h C3.00
Installation Guidance
Fire doors are typically installed as normally closed external doors opening in the direction of evacuation. To determine opening direction: stand facing the door with hinges visible - if hinges are on your right, the door opens outward right.
BS476 tested fire rated wooden door with HPL finish showing construction details and fire resistance features Fire rated door installation example showing proper mounting and sealing in commercial building application

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zowor Door Industry Co., Ltd
Location East of Jinniu Road, South of 310 National Hightway, Shuangta Town, Minquan County, Henan Province, China
Contact Person lan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.