Black and Red 1.8KV DC Single Core Electrical Cable For Indoor / Outdoor Solar Installations
TUV UV resistance dual insulated 16mm² PV XLPE Cable with 25 years warranty for 1.8KV DC applications.
Wire: Stranded tinned copper wire, in accordance with IEC60228, VDE0295 Class 5
Internal insulation: Cross-linked polyolefin
Color code: Black, red
Outer sheath: Cross-linked polyolefin
Sheath colors: Black, red
These cables are designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.
- DIN EN 50618
- Fire-resistance performance: IEC 60332-1
- Low smoke emission: EN/IEC 61034-2
- Halogen free according to EN 50525-1, Annex B
- Low corrosivity of gases according to EN 50267-2-2, IEC 60754-2
- Working voltage: AC: 600/1000V DC: 1800V
- Maximum Voltage: 1.8KV
- Test Voltage: 6.5kV AC
- Working Temperature: -40°C to +90°C
- Bending Radius: Fixed: 4 × overall diameter; Flexed: 5 × overall diameter
- Max. Conductor temperature: 120°C
- Short-circuit max. Conductor temperature: 250°C
- Insulation resistance: 10 MΩ × km
| Type | Cross section (mm²) | Strand design | Conductor diameter (mm) | Conductor resistance (Ω/km) | Outer diameter (mm) | Rated voltage (VAC/DC) | Rated current (A) | Weight (Kg/km) |
|---|---|---|---|---|---|---|---|---|
| PV-1*1.5 mm² | 1.5 | 30x ø 0.25 | 1.6 | 13.5 | 4.8 | 1000/1800 | 30 | 35 |
| PV-1*2.5 mm² | 2.5 | 50x ø 0.25 | 2.0 | 8.21 | 5.3 | 1000/1800 | 41 | 50 |
| PV-1*4.0 mm² | 4.0 | 56x ø 0.3 | 2.6 | 5.09 | 6.1 | 1000/1800 | 55 | 70 |
| PV-1*6.0 mm² | 6.0 | 84x ø 0.3 | 3.3 | 3.39 | 7.1 | 1000/1800 | 70 | 95 |
| PV-1*10.0 mm² | 10.0 | 80x ø 0.4 | 4.4 | 1.95 | 8.5 | 1000/1800 | 98 | 155 |
| PV-1*16 mm² | 16.0 | 120x ø 0.4 | 5.2 | 1.24 | 10.2 | 1000/1800 | 132 | 230 |
| PV-1*25 mm² | 25.0 | 196x ø 0.40 | 7.4 | 0.795 | 12.0 | 1000/1800 | 176 | 341 |
| PV-1*35 mm² | 35.0 | 276x ø 0.40 | 9.00 | 0.565 | 14.0 | 1000/1800 | 218 | 467 |
- Electron beam cross-linked materials do not melt or flow, even at high temperature
- High resistance against heat, cold, abrasion, UV, ozone and hydrolyses
- Interconnect between photovoltaic (PV) panels and from panels to the inverter
- Operate at DC voltage with long life in exposed conditions
Name: PV Cable
Application: Widely used in indoor and outdoor solar installations, electrical installation, industrial and agricultural industries
Features: Low smoke without halogen, good cold, ultraviolet, ozone-resistant and weather-resistant
Flame retardant: Cutting resistance and penetration resistance
Cable protection: Level Ⅱ level
- The DC resistance: ≤ 5.09 Ω/km at 20°C
- The insulation resistance: ≥ 10¹⁴ Ω.cm at 20°C; ≥ 10¹¹ Ω.cm at 90°C
- The sheath surface resistance: ≥ 10⁹ Ω
Conductor: Tinned copper wire 2.5, 4, 6, 10, 16 mm² PV1-F
Insulation: > 0.5mm thick with low smoke and halogen material
Sheath: Low smoke and halogen free material thickness > 0.5mm
Ambient temperature: -40°C to +90°C
Maximum conductor temperature: 120°C (allow 5s in short circuit temperature 200°C)
Limited voltage: AC 0.6/1kV DC 1.8kV
Within 24 hours of getting the inquiry. For urgent pricing, please call us with complete specifications.
Usually within 3-4 working days after payment, depending on quantity.
We accept T/T (bank transfer), L/C.
Yes, we do.
Yes. OEM & ODM are available.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.