KUS630 ultrasonic water level sensor monitoring system of 8 meter detection and uart based
KUS630 Series Ultrasonic Level Meter
1.Features
- KUS630 DTU conforms to the environmental data transmission protocol;
- Low-power RS485 design: 10000mA 5V battery, which can theoretically be used for more than 3 years;
- Using waterproof and anti-corrosion materials, the protection level reaches IP68, especially suitable for water level monitoring applications in rivers and wells;
- The intelligent data terminal can be powered on to enter the working state, and can control the data transmission state.
2.Introduction
The anti-corrosion ultrasonic level gauge is a digital level gauge controlled by a microprocessor. In the measurement, the pulsed ultrasonic wave is sent by the sensor (transducer), the sound wave is reflected by the surface of the object and received by the same sensor, converted into an electrical signal, and the distance between the sensor and the measured object is calculated by the time between the emission and reception of the sound wave. . Because the anti-corrosion ultrasonic liquid level gauge adopts non-contact measurement, the measured medium is almost unlimited, and it can be widely used in the measurement of the height of various liquid and solid materials.
3. Dimensions
Unit in the diagram is mm
4.Electrical connections and signal definitions
| Line order | Colour | Definition |
| 1 | Red | Power is positive |
| 2 | Black | power return ground |
| 3 | Yellow | Analog output, voltage output, current output switch output |
| 4 | Blue | RS485 A+ or uart TXD |
| 5 | Green | RS485 B- or uart RXD |
| Cable color | Line order | Describe | Remark |
| red | 1 | powered by | 3.3V-30V wide voltage input |
| black | 2 | GND | |
| yellow | 3 | Switch output | Switch terminal, load capacity 1A 60V, supports up to two switch outputs with independent logic, the two terminals are the two contacts of the switch, do not distinguish between positive and negative poles, and can be connected at will. |
| White | 4 | Switch output | |
| brown | 4 | RS485A+ | |
| green | 5 | RS485B- |
5.Parameter description
| Model:KUS630 | |
| Measuring range |
0.6m... 10m |
|
Blind spot |
0 ... 0.6m(Unstable working area is within 0.6m, it is not recommended to work in this range); the minimum blind area version of 0.3m can be achieved, which needs to be customized. |
| Supply voltage | 3.3 ... 24 V DC , ripple 10 %SS |
|
Working current |
≤ 45 mA (fastest measurement speed) Low-power version, sleep power consumption is less than 0.3mA, sending power consumption is 20mA (less than 2ms), and receiving power consumption is not more than 8mA (less than 150ms) |
|
Output signal |
1:Programmable analog output 0-10V. 2:RS485 output. 3:Uart serial output 4:4-20mA output 5:Switch output |
| Measurement accuracy | ≤1 % |
| Temperature compensation | yes |
working conditions
| Working temperature | -25…70℃(248...343K) |
| Storage temperature | -40…85℃(233...358K) |
Other instructions
| Electrical connection | 5-core cable (analog output), 6-core cable (switch output); |
| Protection class | IP68 |
| Shell material | PTFE/PVDF |
6.More information
The ultrasonic object/liquid level meter is installed on the upper part of the container. Under the functional control of the combination unit and electronic components, the probe emits a beam of ultrasonic pulses above 20000Hz to the measured object. Since temperature has an effect on the speed of sound, the meter should measure the temperature to correct for the speed of sound. There are many options for the four-wire system, which can simultaneously bring 4-20mA, RS485 communication, two relay outputs, and can also be powered by 220VAC.
7. Ordering Information
| KUS | Model | Output | Range | Describe |
| 630B | Support customization | |||
| Custommade | ||||
| 0-10V | Analog 0-10V output | |||
| 0-5V | Analog 0-5V output | |||
| 0-3V | Analog 0-3V output | |||
| 4-20mA | Analog 4-20mA output | |||
| SW | Switch output | |||
| Uart | Uart serial output MODBUS RTU protocol | |||
| RS485 | RS485 output MODBUS RTU protocol | |||
| XXX mm |
XXX mmmeans the maximum measurement distance (default1000mm) |
|||
| KUS | 550 | RS485 | 10000mm | |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.