KUM2500A Noncontact Clamp On Level Sensor For Water / Fuel Level Measurement
KUM2500A clamp on level sensor for water / fuel level measurement without drilling hole on tank
Introduction
KUM2500A a sensor device that uses ultrasonic detection technology to measure the non-contact liquid level height of oil and liquid substances. It has a built-in anti-interference data processing model to intelligently filter and compensate for environmental interference. It is suitable for containers of various materials such as metal and plastic. It can be networked to realize network monitoring. manage.
When measuring, the ultrasonic probe is installed directly below (bottom) the outer wall of the measured container, without opening holes, easy to install, and does not affect on-site production.
Working Principle
KUM2500A ultrasonic level sensor uses the ultrasonic echo ranging principle. At the same time, it is combined with digital signal processing technology, it overcomes the influence of the container wall, realizes high-precision non-contact measurement of the liquid level in the container, and can meet the requirements of industrial applications in application.

Application
- Internet of vehicles solutions
- Industrial control - textile mills
- Rainwater monitoring
- Road water monitoring
- Fleet management
Features
- non-contact measurement
- It can be used in various complex working conditions such as highly toxic and highly corrosive; as well as inflammable and explosive dangerous occasions
- Installation can stop production, do not clear tanks, and do not affect production
Technical Parameter
| No. | Item | Introduction |
| 1 | Working Voltage | DC 9V~36V. |
| 2 | Working Temperature | -30℃~+80℃ |
| 3 | Storage temperature | -40℃~+85℃. |
| 4 | Measure Range | 3~100cm (4m can be customized). |
| 5 | Maximum power consumption | 0.36W/12VDC |
| 6 | Measurement accuracy | ±0.5%FS |
| 7 | Measurement resolution | 0.1mm |
| 8 | Inbreaking Protection | IP67 |
| 9 | Peripheral interface | RS232 / RS485 / TTL |
| 10 | Tank Materials | conventional fuel tanks such as aluminium alloy/iron/plastic |
| 11 |
Communication port parameter |
default baud rate is 9600 (the baud rate can be configured), no parity bit, 8 data bits, 1 stop bit, and no flow control. |
• For 5mm thick Q235 type steel plate, with No. 0 diesel, the measuring range is 3~100cm
• The rest is based on the actual height measured, depending on the material and thickness of the container.
RS232:

RS485: