4. Description of Sensor Functions
Adjust the parameter
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB,A2 with +UB. Eight different output functions can be set.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power on. If want to change the switching point, the user can only setting the request distance after power restart.
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with - UB
- Set target to far switching point
- TEACH-IN switching point A2 with + UB
TEACH-IN window mode, normally-closed function
- Set target to far switching point
- TEACH-IN switching point A2 with - UB
- Set target to near switching point
- TEACH-IN switching point A1 with + UB
TEACH-IN switching point, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with - UB
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with + UB
TEACH-IN switching point, normally-closed function
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with - UB
- Set target to near switching point
- TEACH-IN switching point A1 with + UB
TEAC-IN large hysteresis interval, normally-open mode
- Set target to near switching point
- TEACH-IN switching point A1 with + UB
- Set target to far switching point
- TEACH-IN switching point A2 with - UB
TEAC-IN large hysteresis interval, normally-closed mode
- Set target to far switching point
- TEACH-IN switching point A2 with + UB
- Set target to near switching point
- TEACH-IN switching point A1 with - UB
TEACH-IN detection of objects presence normally open mode
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with - UB
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with + UB
TEACH-IN detection of objects presence normally closed mode
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with +UB
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with -UB
Default setting of switching point
A1=blind range,A2=nominal distance
LED displays
| Displays in dependence on operating mode |
Red LED |
Yellow LED |
| TEACH-IN switching point Object detected No object detected Object uncertain(TEACH-IN invalid) |
off flashes On |
flashes off off |
| Normal operation |
off |
Switching state |
| Fault |
on |
Previous state |